Text (statement)

Syntax

Text x,y,width,height,title$ [,[.Identifier] [,[FontName$] [,[size] [,style]]]]

Description

Defines a text control within a dialog box template. The text control only displays text; the user cannot set the focus to a text control or otherwise interact with it.

Comments

The text within a text control word-wraps. Text controls can be used to display up to 32K of text.

The Text statement accepts the following parameters:

 

Parameter

Description

 

x, y

Integer positions of the control (in dialog units) relative to the upper left corner of the dialog box.

 

width, height

Integer dimensions of the control in dialog units.

 

title$

String containing the text that appears within the text control. This text may contain an ampersand character to denote an accelerator letter, such as "&Save" for Save. Pressing this accelerator letter sets the focus to the control following the Text statement in the dialog box template.

 

Identifier

Name by which this control can be referenced by statements in a dialog function (such as DlgFocus and DlgEnable). If omitted, then the first two words from title$ are used.

 

FontName$

Name of the font used for display of the text within the text control. If omitted, then the default font for the dialog is used.

 

size

Size of the font used for display of the text within the text control. If omitted, then the default size for the default font of the dialog is used.

 

style

Style of the font used for display of the text within the text control. This can be any of the following values:

 

 

ebRegular

Normal font (that is, neither bold nor italic)

 

 

ebBold

Bold font

 

 

ebItalic

Italic font

 

 

ebBoldItalic

Bold-italic font

 

 

If omitted, then ebRegular is used.

Example

Sub Main()

  Begin Dialog UserDialog 81,64,128,60,"Untitled"
    CancelButton 80,32,40,14
    OKButton 80,8,40,14
    Text 4,8,68,44,"This text is displayed in the dialog box."
  End Dialog
  Dim d As UserDialog
  Dialog d
End Sub

See Also

CancelButton (statement); CheckBox (statement); ComboBox (statement); Dialog (function); Dialog (statement); DropListBox (statement); GroupBox (statement); ListBox (statement); OKButton (statement); OptionButton (statement); OptionGroup (statement); Picture (statement); PushButton (statement); TextBox (statement); Begin Dialog (statement), PictureButton (statement).

Note

Accelerators are underlined, and the Alt+letter accelerator combination is used.

8-point MS Sans Serif is the default font used within user dialogs.