The following table lists the categories of files that are:
Excluded from the Base
Configuration.
Individually Managed
Individually managed files are included in both the Excluded from Base Configuration list and Individually Managed lists.
Base Configuration
Essentially the base configuration files are all files not included in the Excluded from Base Configuration list.
Excluded from Base Configuration |
Individually Managed |
Included Base Configuration |
\COMPUTER.GEF |
|
|
\.PCMFILE |
|
|
*.AMV |
*.AMV |
|
*.ASC |
*.ASC |
|
*.BACKUP |
|
|
*.BCD |
*.BCD |
|
*.BCL |
*.BCL (Except, see below) |
|
*.BCLRT |
*.BCLRT |
|
*.CIM |
*.CIM (Except, see below) |
|
*.CIMRT |
*.CIMRT |
|
*.CLG |
|
|
*.CLM |
*.CLM |
|
*.CMS |
*.CMS |
|
*.CMSRT |
*.CMSRT |
|
*.CTX |
*.CTX |
|
*.ERR |
|
|
*.FAV |
|
|
*.INI (That are not in Base Config) |
*.INI (Except, see below and not in Base Config.) |
DATA\GLOBALS.INI |
|
|
DATA\master_pos_0.ini |
|
|
DATA\MASTER_POS_63.ini |
|
|
DATA\S90TRIO.ini |
|
*.HTM |
|
|
*.HTML |
|
*.LOCK |
|
|
*.OCX |
|
|
*.PP |
*.PP |
|
*.PPL |
*.PPL |
|
*.PRO |
*.PRO |
|
*.QTR |
*.QTR |
|
*.REG |
|
|
*.RGP |
*.RGP |
|
*.RTF |
|
|
*.SOC |
*.SOC |
|
*.SPC |
*.SPC |
|
*.STG |
|
|
*.TXT (That are not in Base Config) |
PERFSERV\DEFAULTCOUNTERS.TXT |
ETC\CIMHOSTS.TXT |
*.XLS |
|
|
*.XML (That are not in Base Config) |
|
DATA\CIMOPCSERVER.XML |
AEOPC\*.* |
|
|
API\*.* |
|
|
ARC\*.MDB |
|
|
BSM_DATA\*.* |
|
|
CIMPOLE\*.* |
|
|
CLASSES\*.* |
|
|
CNC\*.* |
CNC\*.* |
|
CNC_SETUP\*.* |
|
|
DATA\*.IDX |
|
|
DATA\*.IDT |
|
|
DATA\AMLP.CFG |
|
|
DATA\CIMCMSAFE.CFG |
DATA\CIMCMSAFE.CFG |
|
DATA\*.CACHE |
|
|
DATA\DATALOG.DAT |
|
|
DATA\GEFKEYPAD.CFG |
DATA\GEFKEYPAD.CFG |
|
DATA\LOGPROC.DAT |
|
|
DATA\NODE.DAT |
|
|
DATA\OPCINISETTINGS.CFG |
DATA\OPCINISETTINGS.CFG |
|
DATA\PROJSHARES.DAT |
|
|
DATA\PTMGMT.DAT |
|
|
DATA\SERVICE.DAT |
|
|
DC\*.* |
|
|
DOCS\*.* |
|
|
ETC\*.TXT |
|
|
EXE\*.* |
|
|
EXTRAS\*.* |
|
|
FIREWALL\SP2MANAGER.DLL |
|
|
FIREWALL\SP2MANAGEREXE.EXE |
|
|
FONTS\*.* |
|
|
GEFVCR\*.* |
|
|
HELP\*.* |
|
|
LOG\*.* |
|
|
MDAC\*.* |
|
|
MSSQL*\*.* |
|
|
OPCSERVER\*.* |
|
|
OPT\*.* |
|
|
PAGER\INSTALL.LOG |
|
|
PAGER\UNWISE.ENG |
|
|
PAGER\UNWISE32.EXE |
|
|
PAGER\BACKUP\ |
|
|
PAGER\DATA\FPADMIN.MDB |
PAGER\DATA\FPADMIN.MDB |
|
PAGER\DATA\FPSERVER.MDB |
PAGER\DATA\FPSERVER.MDB |
|
PAGER\DBSCRIPTS\*.* |
|
|
PAGER\EXAMPLES\*.* |
|
|
PAGER\EXE\*.* |
|
|
PAGER\LIBS\*.* |
|
|
PAGER\LOGS\*.* |
|
|
PAGER\MANUALS\*.* |
|
|
PAGER\REPORTS\*.* |
|
|
PERFSERV\*.* |
|
|
POMS\*.* |
|
|
PROJECTS\*.* |
|
|
DATA\PTOPC_CONFIG.XML |
DATA\PTOPC_CONFIG.XML |
|
PUBLISHSUBSCRIBEDELIVERY\*.* |
|
|
RCO\*.* |
|
|
REPORT\*.* |
|
|
SCRIPTS\*.* |
|
|
SERIES90\*.* |
|
|
SETUP\*.* |
|
|
SYMBOLS\*.* |
SYMBOLS\*.* |
|
SYSTEMSENTRY\*.* |
SYSTEMSENTRY\*.* |
|
TADB\*.* |
|
|
TQE\*.* |
|
|
TRACKER\*.* |
|
|
UNINSTALL\*.* |
|
|
WEBPAGES\*.* |
|
|
|
|
All other files not listed in this table or as exceptions. |
Files that are Exceptions to the Rule
The following files may be types that are individually managed. However, these specific files are excluded from computer project management.
\_CONFIG.INI
API\REDUNDANT_API\[_A-Z0-9].*\.BCL
BSM_DATA\[_A-Z0-9].*\.BCL
BSM_DATA\[_A-Z0-9].*\.INI
DATA\GLOBALS.INI
EXE\[_A-Z0-9].*\.INI
EXTRAS\THINVIEW\SCREENS\[_A-Z0-9].*\.CIM
\FIREWALL.*
PAGER\EXAMPLES\[_A-Z0-9].*\.BCL
PERFSERV\[_A-Z0-9].*\.H
PERFSERV\MACROS.IDT
PERFSERV\[_A-Z0-9].*\.INI
SERIES90\[_A-Z0-9].*\.CIM
Proficy Change Management technical reference. |