When Quick Launch buttons are included on the Navigation bar, the button order from left to right is as follows.
A |
Left |
Quick Launch buttons . |
B |
Right |
Extended menu button. |
Note: A quick Launch button can be added or deleted from the navigation configuration at any time.
Methods to add a Quick Launch button are as follows.
Drag and drop a screen. |
|
Use the Navigation Configuration Editor's menu items. |
Drag and drop a screen
Note: Dragging and dropping a screen speeds up configuration when the Quick Launch button will use an Overlay action type.
Collapse the extended menu.
Select a screen in the Navigation Configuration window lower right pane.
Drag the screen to Navigation Configuration in the left pane.
The screen file name is listed in the Navigation path at the same level as the extended menu root node.
(Optional) Rename the node name.
Select the root node.
Do one of the following.
Right-click the name; select Rename on the Popup menu.
Select Edit>Rename on the Configuration Editor menu bar.
Press F2 on the keyboard.
The name can now be edited.
Type in the name that should display on the menu bar.
(Optional) Change the icon.
When the screen is dragged to create the node, the default icon will display in the tree. The icon can be changed.
Select the quick launch node.
Do one of the following.
Click Edit>Change Icon on the Navigation Configuration Editor menu bar.
Right-click the quick launch node; select Change Icon on the Popup menu.
Select the icon you want to use for the node.
Result: The Quick Launch node will now display on the menu bar; the screen that will display is automatically entered in the Overlay parameters Screen name field.
Use the Navigation Configuration Editor's Menu Items
Select the Navigation Configuration object in the Navigation Configuration editor left pane.
Do one of the following.
Right-click Navigation Configuration; select Add Configuration Object on the Popup menu.
Click Edit>Add Configuration object on the Navigation Configuration Editor menu bar.
An Add Configuration Object dialog box opens.
Enter the following.
Field |
Description |
|
Name |
Name that will display on the Menu bar. |
|
Type |
The Navigation Node is the object that a user will click on to open a screen or run a script. |
|
Icon |
An icon can be selected from the icon drop down list to represent the node. The icon selection will depend on your system's specifications and whether or not you use custom icons. |
|
|
Default |
Note: The default icon for a node may be different, based on your system's icon list. |
Click
.Result: The Add Configuration Object dialog box closes; The name that was entered displays as the root node name in the Navigation Configuration window left pane.
Important: When the root is added using the Add Configuration Object dialog box, an action type and specifications required for that action type will have to be entered before the navigation configuration can be saved with no errors.
Step 3. Define quick launch buttons. |