Gets the product by name. | |
Syntax: | CimProduct* = object.Item ( ProductID ) |
Parameters: |
ProductID As
String - Product name to be
retrieved.
|
Description: | DCimProductList.Item returns a CimProduct by name. If you want to
enumerate all the products in the list without knowing the names
use a For Next loop instead if Item. Example: Dim pSystem As CimSystem Set pSystem = CreateObject("CimSystem") Dim productsList as CimProductList Set productsList = pSystem.InstalledProducts Dim productItem As CimProduct For Each productItem In productsList MsgBox productItem.Description Next productItem Example: Dim pSystem As CimSystem Set pSystem = CreateObject("CimSystem") Dim productsList as CimProductList Set productsList = pSystem.InstalledProducts Dim productItem As CimProduct Set productItem = productsList.Item("IC646THC000") If Not productItem Is Nothing Then MsgBox productItem.Description End If |