Purpose
The command line utility cnc_upload_tool.exe uploads CNC file data from CNC memory to files on the PC.
Correct usage
C:\> cnc_upload_tool <data> <nodenum> <pathnum> <filespec.csv> <start> <end>
Usage defined
<data> |
CNC file data. Enter one of the following. |
||
|
parm |
Parameter Data |
|
|
tofs |
Tool Offset Data |
|
|
zofs |
Work Zero Offset Data |
|
|
cmv |
Custom Macro Variable Data |
|
|
pec |
Pitch Error Compensation |
|
|
kbit |
Keep Relay Data |
|
|
diag |
Diagnostic Data |
|
<nodenum> |
Node number (configured HSSB card). |
||
<pathnum> |
Path to the CNC. Enter one of the following. |
||
|
Value |
Path |
|
|
0 |
None |
|
|
1 |
First |
|
|
2 |
Second |
|
|
3 |
Third |
|
|
4 |
Fourth |
Series 300i/310i/320i only |
|
5 |
Fifth |
Series 300i/310i/320i only |
|
6 |
Sixth |
Series 300i/310i/320i only |
|
7 |
Seventh |
Series 300i/310i/320i only |
|
8 |
Eighth |
Series 300i/310i/320i only |
|
9 |
Ninth |
Series 300i/310i/320i only |
|
10 |
Tenth |
Series 300i/310i/320i only |
|
If the CNC does not support multiple paths, enter 0. |
||
<filespec> |
File specification of file to receive the uploaded data. This may be a fully qualified filename or a filename in the current directory in comma separated variable (.csv) format. |
||
<start> |
Starting range of file data to upload. |
||
<end> |
Ending range of file data to upload. |
||
|
If both the start and end are left blank, all of the specified data for the CNC is uploaded. |
Example
The contents of the CNC parameter data table between <start> and <end> are uploaded to the <filespec> for <nodenum>and <pathnum>:
C:\> cnc_upload_tool parm 0 0 parm1000.csv 1 1000
Uploading parm 0001 - 1000 to parm1000.csv: Success
C:\>
The file parm1000.csv is either created or overwritten with all the parameters in the range of 1 to 1000 currently registered in CNC memory. The file upload_tool_log.csv is either created or overwritten with any errors during the upload.
In the following example, the entire contents of the CNC parameter data table is uploaded to the <filespec> for <nodenum>and <pathnum>:
C:\> cnc_upload_tool parm 0 0 parmall.csv
Uploading all parm to parmall.csv: Success
C:\>
The file parmall.csv is either created or overwritten with all the parameters currently registered in CNC memory. The file upload_tool_log.csv is either created or overwritten with any errors during the upload.
The following is a list of possible errors:
Could not determine CNC type for
node x.
Could not link to DLL.
Failure to get directory info.
Bad directory info returned.