A Data

A Data definition.

Configure digital points to reference individual bits.

Configure analog points to reference individual bytes, words, or longwords.

Supported addresses.

A Data definition

A Data

Is for message demand.

A data points

Are read and write.

Digital points to reference individual bits

Point Class

DIGITAL

Type

BOOL

Access

Read or Read/Write

Valid Addresses

Axxxx, where xxxx is a valid address for your PMC type

Address Offset

0-7, for the particular bit you want to reference

Analog points to reference individual bytes, words, or longwords

Point Class

ANALOG

Type

SINT, INT, or DINT (1, 2, or 4 bytes)

Access

Read or Read/Write

Valid Addresses

Axxxx, where xxxx is a valid address for your PMC type

Address Offset

none

Supported addresses

CNC

PMC Type

Valid Address Range

Series 150

NA/NB

A0000-A0024

 

NB2

A0000-A0124

Series 150i

NB6

A0000-A0124

Series 160/180-B/C

SA1/SB3/SB5/SC3

A0000-A0024

 

SB4/SB6/SC4

A0000-A0124

Series 210-B, 0i-A

SA1/SA3

A0000-A0024

Series 160i/180i, 0i-B(SB7)

SB5

A0000-A0024

SB6

A0000-A0124

 

SB7

A0000-A0249,

A9000-A9249

Series 210i, 0i-B(SA1)

SA1/SA5

A0000-A0024

Power Mate

All

A0000-A0024

Power Mate i

SB5

A0000-A0024

 

SB6

A0000-A0124

CNC

1st PMC

*2nd PMC

*3rd PMC

Series 300i/310i/320i

 

 

 

 

Message Display

A0000-A0249

A0000-A0249

A0000-A0249

 

Status Display

A9000-A9249

A9000-A9249

A9000-A9249

* Optional

**

More information

PMC BMI Bits