Note: Bits for Custom Macro variables are
purchase options.
Custom Macro Variable guidelines. |
|
Custom Macro Variable attributes. |
|
Custom Macro Variable restrictions. |
Custom Macro Variable guidelines
Variable Type |
Guidelines |
Local |
You cannot write Local common variables (CMV1-CMV33). |
Vacant |
Individual custom macro variables may be vacant on the CNC. Vacant macro variables are not currently assigned a value. A point that is reading a vacant custom macro variable will have a value of 0. |
Custom Macro Variable attributes
When configuring points for Custom Macro Variable Data, specify the following attributes:
Point Class |
ANALOG |
|
Type |
REAL |
|
Access |
READ or READ/WRITE |
|
CNC |
Valid Addresses |
Variable Types |
Series 150 M/T |
CMV1-CMV33 |
Local Macro Variables |
|
CMV100-CMV149, CMV500-CMV531 |
Macro Variable |
|
CMV100 - CMV149, CMV500 - CMV549 or |
|
|
CMV100 - CMV199, CMV500 - CMV599 or |
|
|
CMV100 - CMV199, CMV500 - CMV699 or |
|
|
CMV100 - CMV199, CMV500 - CMV999 |
|
Series 150i |
CMV1 - CMV33 |
Local Macro Variables |
|
CMV100 - CMV199, CMV500 - CMV999 or |
Macro Variables |
|
CMV100 - CMV199, CMV200 - CMV999 |
|
Series 15TT |
CMV1 - CMV33 |
Local Macro Variables |
|
CMV100 - CMV149, CMV500 - CMV524 or |
Macro Variables |
|
CMV100 - CMV149, CMV500 - CMV549 or |
|
|
CMV100 - CMV149, CMV500 - CMV599 or |
|
|
CMV100 - CMV149, CMV500 - CMV749 |
|
Series 160/180, 160i/180i, 0i |
CMV1 - CMV33 |
Local Macro Variables |
|
CMV100 - CMV149, CMV500 - CMV531 or |
Macro Variables |
|
CMV100 - CMV199, CMV500 - CMV999 or |
|
|
CMV100 - CMV199, CMV500 - CMV599 |
|
Series 160i/180i W |
CMV1 - CMV33 |
Local Macro Variables |
|
CMV100 - CMV149, CMV500 - CMV531 or |
Macro Variables |
|
CMV100 - CMV314, CMV500 - CMV699 or |
|
|
CMV100 - CMV149, CMV500 - CMV699 or |
|
|
CMV100 - CMV314, CMV500 - CMV531 or |
|
|
CMV100 - CMV149, CMV500 - CMV999 or |
|
|
CMV100 - CMV314, CMV500 - CMV999 |
|
Series 300i/310i/320i |
CMV1 - CMV33 |
Local Macro Variables |
|
CMV100 - CMV149, CMV500 - CMV549 or |
Macro Variables |
|
CMV100 - CMV199, CMV500 - CMV999 or |
|
|
CMV100 - CMV149, CMV200 - CMV499, CMV500 - CMV549 or |
|
|
CMV100 - CMV199, CMV200 - CMV499, CMV500 - CMV999 |
|
Power Mate, Power Mate i-D/H |
CMV1 - CMV33 |
Local Macro Variables |
|
CMV100 - CMV149, CMV500 - CMV549 or |
Macro Variables |
|
CMV100 - CMV199, CMV500 - CMV999 or |
CMV100 - CMV149, CMV200 - CMV499, CMV500 - CMV549 or |
|
CMV100 - CMV199, CMV200 - CMV499, CMV500 - CMV999 |
|
Address Offset |
None |
|
Custom Macro Variable restrictions
Guidelines
When writing P Code Macro Variables that support the real (floating-point) data type, please be aware that the available range is 999999999,...,-999999999.
Supported Data Types. |