D Data definition. |
|
Digital points to reference individual bits configuration. |
|
Analog points to reference individual bytes, words, or longwords configuration. |
|
Supported addresses. |
D Data definition
D Data |
Is to access the data table. |
D data points |
Are read and write. |
Digital points to reference individual bits
Point Class |
DIGITAL |
Type |
BOOL |
Access |
Read or Read/Write |
Valid Addresses |
Dxxxx, where xxxx is a valid address for your PMC type |
Address Offset |
0-7, for the particular bit you want to reference |
Analog points to reference individual bytes, words, or longwords
Point Class |
ANALOG |
Type |
SINT, INT, or DINT (1, 2, or 4 bytes) |
Access: |
Read or Read/Write |
Valid Addresses |
Dxxxx, where xxxx is a valid address for your PMC type |
Address Offset |
none |
Supported addresses
CNC |
PMC Type |
Valid Address Range |
||
Series 150 |
NA/NB |
D0000-D0299 |
||
|
NB2 |
D0000-D7999 |
||
Series 150i |
NB6 |
D0000-D7999 |
||
Series 160/180-B/C |
SA1 |
D0000-D1859 |
||
|
SB3/SB5/SC3 |
D0000-D2999 |
||
|
SB4/SB6/SC4 |
D0000-D7999 |
||
Series 210-B, 0i-A |
SA3 |
D0000-D1859 |
||
Series 160i/180i, 0i-B(SB7) |
SB5 |
D0000-D2999 |
||
SB6 |
D0000-D7999 |
|||
|
SB7 |
D0000-D9999 |
||
Series 210i, 0i-B(SA1) |
SA1/SA5 |
D0000-D1859 |
||
Power Mate |
All |
D0000-D1859 |
||
Power Mate i |
SB5 |
D0000-D2999 |
||
SB6 |
D0000-D7999 |
|||
CNC |
1st PMC |
*2nd PMC |
*3rd PMC |
|
Series 300i/310i/320i |
D0000-D9999 |
D0000-D2999 |
D0000-D2999 |
* Optional
Note: The CRT/MDI panel and the CNC Screens provide the ability to display D data individual bits, and as longwords from the Data screen. To have software display the data in the same format, configure points as type DINT.
PMC BMI Bits |