K Data definition. |
|
Digital points to reference individual bits configuration. |
|
Analog points to reference individual bytes, words, or longwords configuration. |
|
Supported addresses. |
K Data definition
K Data |
Is for keep relays. |
K data points |
Are read and write. |
Digital points to reference individual bits
Point Class |
DIGITAL |
Type |
BOOL |
Access |
Read or Read/Write |
Valid Addresses |
Kxxxx, where xxxx is a valid address for your PMC type |
Address Offset |
0-7, for the particular bit you want to reference |
Analog points to reference individual bytes, words, or longwords
Point Class |
ANALOG |
Type |
SINT, INT, or DINT (1, 2, or 4 bytes) |
Access |
Read or Read/Write |
Valid Addresses |
Kxxxx, where xxxx is a valid address for your PMC type |
Address Offset |
none |
Supported addresses
CNC |
PMC Type |
Valid Address Range |
|||
Series 150 |
NA |
K0000-K0018 |
|||
|
NB |
K0000-K0019 |
|||
|
NB2 |
K0000-K0039, K0900-K0909 |
|||
Series 150i |
NB6 |
K0000-K0039, K0900-K0909 |
|||
Series 160/180-B/C |
SA1/SB3/SB5/SC3 |
K0000-K0019 |
|||
|
SB4/SB6/SC4 |
K0000-K0039, K0900-K0909 |
|||
Series 210-B, 0i-A |
SA1/SA3 |
K0000-K0019 |
|||
Series 160i/180i, 0i-B(SB7) |
SB5 |
K0000-K0019 |
|||
SB6 |
K0000-K0039, K0900-K0909 |
||||
|
SB7 |
K0000-K0099, K0900-K0919 |
|||
Series 210i, 0i-B(SA1) |
SA1/SA5 |
K0000-K0019 |
|||
Power Mate |
All |
K0000-K0019 |
|||
Power Mate i |
SB5 |
K0000-K0019 |
|||
|
SB6 |
K0000-K0039, K0900-K0909 |
|||
CNC |
1st PMC |
*2nd PMC |
*3rd PMC |
||
Series 300i/310i/320i |
|
|
|
||
|
User Range |
K0000-K0099 |
K0000-K0019 |
K0000-K0019 |
|
|
System Range |
K0900-K0999 |
K0900-K0999 |
K0900-K0999 |
* Optional.
Note: The CRT/MDI panel and the CNC Screens
provide the ability to display K data as individual bits. To
configure points to display data in the same format, configure
DIGITAL points of type BOOL.
Caution: If you have an NA, NB, RA1, RA3, RB3,
or and RC3 PMC, you must not write to Keep Relay locations
K0017-K0019. If you have an RB4 or an RC4 PMC, you must not write
Keep Relay locations K0900-K0909. CIMPLICITY software will not
prevent you from writing to these memory locations.
PMC BMI Bits |