Machining Series - Memory Type C

Point types that can be configured for Machining series - Memory Type C include:

Tool length / Geometry offsets.

Tool length / Wear offsets.

Cutter radius / Geometry offsets.

Cutter radius / Wear offsets.

Direction of imaginary tool nose (Series 300i/310i/320i only).

Tool Length / Geometry Offsets

Point Class

ANALOG

Type

REAL

Access

Read-only or Read/Write

Valid Addresses

TLGx, where x is a valid tool offset number for your CNC

Address Offset

N/A

Tool Length / Wear Offsets

Point Class

ANALOG

Type

REAL

Access:

Read-only or Read/Write

Valid Addresses

TLWx, where x is a valid tool offset number for your CNC

Address Offset

N/A

Cutter Radius / Geometry Offsets

Point Class

ANALOG

Type

REAL

Access

Read-only or Read/Write

Valid Addresses

CRGx, where x is a valid tool offset number for your CNC

Address Offset

N/A

Cutter Radius / Wear Offsets

Point Class

ANALOG

Type

REAL

Access

Read-only or Read/Write

Valid Addresses

CRWx, where x is a valid tool offset number for your CNC

Address Offset

N/A

Direction of Imaginary Tool Nose (Series 300i/310i/320i only)

Point Class

ANALOG

Type

REAL

Access

Read-only or Read/Write

Valid Addresses

DITNx, where x is a valid tool offset number for your CNC

Address Offset

N/A

More information

Tool Offset Data