Note: Bits for Tool Management are options you
can purchase .
Important: Tool Management Data is supported
only on Series 160i, 180i, 210i, and 300i/310i/320i .
Point data access. |
|
Point configuration. |
|
Point array elements. |
Point data access
You can configure a point to access the Tool
Management Data table,
including the:
|
T code |
|
|
|
|
|
|
|
|
|
|
|
bit 0 : RGS bit 1 : TIM bit 2 : BDT bit 3 : LOC bit 4,...,15 : Reserved |
|
H code |
|
D code |
|
S code |
|
F code |
|
Read-only |
|
Read-only |
|
G code Turning system only |
|
W code Turning system only |
Point configuration
Specify the following for the Tool Management Data table access points.
Point Class |
ANALOG |
Type |
DINT |
Elements |
15-element array |
Access |
Read/Write |
Valid Addresses |
TOOL<X>, where X is the tool number |
Number of Elements |
15 |
Point array elements
The elements of the Tool Management Data table point array are as follows.
Element 0 |
Tool number (T) |
|||||
|
Setting range |
0 to 99999999 |
||||
Element 1 |
Tool life counter |
|||||
|
Setting range |
0 to 99999999 |
Unit |
count |
||
|
Setting range |
0 to 3599999 |
Unit |
sec |
||
Element 2 |
Maximum of tool life |
|||||
|
Setting range |
0 to 99999999 |
Unit |
count |
||
|
Setting range |
0 to 3599999 |
Unit |
sec |
||
Element 3 |
Predictive tool life |
|||||
|
Setting range |
0 to 99999999 |
Unit |
count |
||
|
Setting range |
0 to 3599999 |
Unit |
sec |
||
Element 4 |
State of tool life |
|||||
|
0 |
Tool is not managed |
||||
|
1 |
Unused tool |
||||
|
2 |
Enable to use |
||||
|
3 |
Life is over |
||||
|
4 |
Tool is broken |
||||
Element 5 |
Customizing Bits |
|||||
Element 6 |
Tool info |
|||||
|
bit 0 |
: RGS |
||||
|
|
0 |
Tool management data is void. |
|||
|
|
1 |
Tool management data is valid. |
|||
|
bit 1 |
: TIM |
||||
|
|
0 |
Tool life is specified by count. |
|||
|
|
1 |
Tool life is specified by time. |
|||
|
bit 2 |
: BDT |
||||
|
|
0 |
Normal tool. |
|||
|
|
1 |
Big tool. |
|||
|
bit 3 |
: LOC |
||||
|
|
0 |
Data accessible. |
|||
|
|
1 |
Data locked. |
|||
|
bit 4,...,15 |
Reserved |
||||
Element 7 |
Tool length compensation number (H) |
|||||
|
Setting range |
0 to 999 |
||||
Element 8 |
Cutter compensation number (D) |
|||||
|
Setting range |
0 to 999 |
||||
Element 9 |
Spindle speed (S) |
|||||
|
Setting range |
0 to 99999 |
Unit |
/min |
||
Element 10 |
Feed rate (F) |
|||||
|
Setting range |
0 to 99999999 |
Unit |
mm/min inch/min deg/min mm/rev inch/rev |
||
Element 11 |
Magazine number |
This data is read-only; it cannot be used for writing data. |
||||
Element 12 |
Pot number |
This data is read-only; it cannot be used for writing data. |
||||
Element 13 |
Tool geometric compensation number (G) |
This data is Turning system only. |
||||
Element 14 |
Tool wear compensation number (W) |
This data is Turning system only. |
||||
|
|
|
|
|
|
|
Note: If the first element of the array point,
element 0, has a value of 0, this indicates that this tool
does not exist. If this is
the case, then you should not try to set the other elements of this
array point.
Supported Data Types. |