X Data

X Data definition.

Digital points to reference individual bits configuration.

Analog points to reference individual bytes, words, or longwords configuration.

Supported addresses.

X Data definition

X Data

Is input data:

 

From

Machine tool

 

To

PMC

X data points

Are read only

Digital points to reference individual bits

Point Class

DIGITAL

Type

BOOL

Access

Read only

Valid Addresses

Xxxxx, where xxxx is a valid address for your PMC type

Address Offset

0-7, for the particular bit you want to reference

Analog points to reference individual bytes, words, or longwords

Point Class

ANALOG

Type

SINT, INT, or DINT (1, 2, or 4 bytes)

Access

Read only

Valid Addresses

Xxxxx, where xxxx is a valid address for your PMC type

Address Offset

none

Supported addresses

CNC

PMC Type

Valid Address Range

Series 150

NA/NB/NB2

X0000-X0127

Series 150i

NB6

X0000-X0127,

X0200-X0327

Series 160/180-B/C

SA1/SB3/SB4/SB5/SB6/SC3/SC4

X0000-X0127,

X1000-X1019,

X1020-X1039

Series 210-B, 0i-A

SA1/SA3

X0000-X0127,

X1000-X1011

Series 160i/180i, 0i-B(SB7)

SB5/SB6/SB7

X0000-X0127

 

SB6/SB7

X0200-X0327

Series 210i, 0i-B(SA1)

SA1/SA5

X0000-X0127

Power Mate

All

X0000-X0127,

X1000-X1063

Power Mate i

SB5/SB6

X0000-X0127,

X1000-X1003,

X1020-X1051

CNC

1st PMC

*2nd PMC

*3rd PMC

Series 300i/310i/320i

X0000-X0127,

X0200-X0327,

X0400-X0527,

X0600-X0727,

X1000-X1127**

X0000-X0127,

X0200-X0327,

X0400-X0527,

X0600-X0727,

X1000-X1127**

X0000-X0127,

X0200-X0327,

X0400-X0527,

X0600-X0727,

X1000-X1127**

*     Optional

**    X1000-X1127 is reserved for PMC management software. No I/O can be allocated in this area. Do not use it in user programs.

More information

PMC BMI Bits