The CNC Part Program Application provides you with an easy to use interface for managing your part programs. Before you begin to use the application, there are some configuration guidelines to consider to ensure that your PC and CNCs are optimized for using the application.
Part Program parameters on the CNC. |
|
Download program parameters. |
|
Upload Program parameters. |
Part Program parameters on the CNC
Series |
Parameter |
|
HSSB |
|
|
|
3202#0,#4,#6
influenced by setting |
|
|
3202#0,#4,#6 influenced by setting |
|
Ethernet |
|
|
|
3202#0,#4,#6 3204#3,#4 3210,3211 |
|
|
3202#0,#4,#6 3204#3,#4 |
|
CNC Mode |
Mode |
Search |
HSSB |
|
|
|
|
Foreground Background |
|
|
Foreground Background |
Ethernet |
|
|
The behavior of this function depends on the CNC mode. |
EDIT, MEM Other |
Foreground Background |
Download program parameters
Downstart |
|
Downstart3 (Ethernet only) |
Series |
Parameter |
Series 150,150i |
0020=16(EDIT mode) must be set 0022=16(except EDIT mode) must be set 0000#0 influenced by setting 2200#1,#3,#4 influenced by setting 0011#0,2201#0 influenced by setting 2210,2211,2212,2213 influenced by setting |
Series 160i/180i/210i, 300i/310i/320i |
0000#0 influenced by setting 3201#2,#5,#6 influenced by setting 3202#0,#4 influenced by setting 3210,3211 influenced by setting 3290#7 influenced by setting |
Series 160i/180i-W, Power Mate i |
0000#0 influenced by setting 3201#2,#5,#6 influenced by setting 3202#0,#4 influenced by setting 3290#7 influenced by setting |
CNC Mode |
Mode |
|
It is possible to use in any CNC mode.(It is necessary to set the parameter according to the mode) |
|
(It is possible to use in other than MDI mode.) |
|
This function can be used in any CNC mode. (It is necessary to set mode according to the target data.) |
Downstart3 (Ethernet only)
Series |
Parameter |
|
Series 150i
|
0020=7(*) must be set 0022=7(*) must be set 0000#0 2200#1,#3,#4 0011#0,2201#0 2210,2211,2212,2213 8000#0 |
|
|
Program |
Use |
|
|
|
|
EDIT Node |
0020 |
|
Not EDIT Mode |
0022 |
|
|
|
|
Background Editing |
0020 |
|
Not Background Editing |
Cannot be used. |
Series 160i/180i/210i, 300i/310i/320i
|
0000#0 3201#2,#5,#6 3202#0,#4 3204#3,#4 3210,3211,8900#0 |
|
Power Mate i
|
0000#0 3201#2,#5,#6 3202#0,#4 3204#3,#4 8900#0 |
|
CNC Mode |
||
This function can be used in any CNC mode. (It is necessary to set mode according to the target data.) |
Upload program parameters
Upstart |
|
Upstart3 |
Series |
Parameter |
|
0021=16 (EDIT mode) must be set 0023=16 (except EDIT mode) must be set |
Series |
Parameter |
|
Series 150i
|
0021=7(*) must be set 0023=7(*) must be set 0000#0 2200#1,#3,#4 0011#0,2201#0 2210,2211,2212,2213 |
|
|
Program |
Use |
|
|
|
|
EDIT Node |
0021 |
|
Not EDIT Mode |
0023 |
|
|
|
|
Background Editing |
0023 |
|
Not Background Editing |
0021 |
Series 160i/180i/210i, 300i/310i/320i |
0000#0 3201#2,#5,#6 3202#0,#4 3204#3,#4 3210,3211 |
|
Power Mate i |
0000#0 3201#2,#5,#6 3202#0,#4 3204#3,#4 |
CNC Part Program. |