There are several different possible views for the ActiveX component based on the status of the delivery object.
Nonexistent Delivery Object |
|
In Configuration |
|
Waiting for Document |
|
In Delivery |
|
Retrieving File |
|
Appending File |
|
Waiting for Retry |
|
Flushing Files |
|
Unresponsive |
Nonexistent Delivery Object
Status |
Description |
Nonexistent |
The delivery object specified by the delivery name parameter for the ActiveX component cannot be found |
Status |
Description |
In Configuration |
The delivery is currently being configured, either on initialization or by dynamic configuration |
Waiting for Document
Status |
Description |
Waiting for Document |
The specified delivery object is waiting for an output document to send. |
Status |
Description |
The specified delivery object is attempting a delivery for the first time. |
Parameter |
Description |
Name of the delivery object being monitored. |
|
Status of the delivery object being monitored, as listed on this page. |
|
Percent Complete |
Percentage complete of the current delivery. Note: This does not include retrieving files for appending. |
Destination File |
Name of the remote file in delivery. |
Failed Attempts |
Number of failed attempts for the current output document. |
Alarm after Failed Attempts |
Number of failed attempts that need to happen before an alarm is sent to the alarm manager. |
Retries to attempt |
Number of times that a failed delivery will be retried before the delivery object will give up and flush the file. |
Unsent Output Documents |
List of all the unsent documents that this delivery object still needs to process. Note: The name of the output document does not need to be the same as the Destination Filename. |
Retrieving File
Status |
Description |
Retrieving File |
The file is being retrieved. If the file being delivered must be appended to an existing file, the existing file must first be retrieved from the destination. |
Appending File
Status |
Description |
Appending File |
File is being appended. The file being delivered must be appended to an existing file, after the file being appended is retrieved from the destination |
Waiting for Retry
Status |
Description |
Waiting For Retry |
Delivery object is waiting for the retry interval time to elapse in order to retry the delivery. Note: All of the text in the ActiveX status object is customizable. There are two different entries that are applicable.
The color of the status text is based on these two entries and whether or not the alarm has been set. |
Flushing Files
Status |
Description |
Flushing Files |
Delivery Object is flushing unsent files. |
Status |
Description |
Unresponsive |
ActiveX control successfully connected to the delivery object but does not receive a status update in a configured time period. |
Configure the Document Delivery Viewer object. |