XML Tags: FTP. |
|
FTP specific guidelines. |
|
Examples: FTP. |
XML Tags: FTP
There is now a mechanism for doing small FTP commands before and after the actual delivery.
For instance, you might be required to manually change the directory before the delivery takes place, and then change the directory back to the root when finished.
To accomplish this, the Pre and Post commands can be used.
XML Tag |
Description |
||||
<Header> |
The main wrapper tag for the XML style header. There are no attributes for this tag |
||||
<DestinationFilename> |
Contains the remote destination filename. There are four attributes for all systems for this tag |
||||
|
Filename |
The remote destination filename to be delivered to. |
|||
|
Rename |
Allows the file to be renamed during the delivery process. Options are: |
|||
|
|
"Yes" |
(Default) The rename feature can be used. |
||
|
|
"No" |
The rename feature cannot be used. Important: If this condition is found on an APPEND type delivery, the delivery will fail; APPEND deliveries must be able to rename. |
||
|
KeepConnectionOpen |
Options are: |
|||
|
|
|
|
"Yes" |
An FTP connection will stay open. |
|
|
|
|
"No" |
An FTP connection is not forced to stay open. |
|
overrideKeepConnectionOpen |
Options are: |
|||
|
|
|
|
"Yes" |
Enables ability to override the open FTP connection so the connection can close. |
|
|
|
|
"No" |
Does not allow an override to the open FTP connection tag. |
PreCommands |
Wrapper for all Pre commands that are to be attempted before the delivery occurs. There are no attributes for this tag. |
||||
PreCommand |
Holds one FTP command to take place before the delivery occurs. The raw FTP command is written verbatim in the command attribute. There is one attribute for this tag. |
||||
|
command |
The command to be sent. |
|||
PostCommands |
Wrapper for all the Post commands that are to be attempted after the delivery is completed. There are no attributes for this tag. |
||||
PostCommand |
Holds one FTP command to take place after the delivery is successfully completed. The raw FTP command is written verbatim in the command attribute. There is one attribute for this tag. |
||||
|
command |
The command to be sent. |
|||
|
|
|
|
|
|
FTP
specific guidelines
Multiple PreCommand and PostCommand tags may be used.
The total size of the header
including the version, null characters and Carriage Return Line
Feed cannot exceed 4096 bytes.
Failures in the delivery process
are treated as follows.
If the following fails: |
Result |
Pre commands |
Delivery and the post commands are not processed. Delivery is considered to be failed. |
Delivery |
Post commands are not processed. Delivery is considered to be failed. |
Post commands |
Delivery is considered to be failed. |
Note: If the actual delivery of the remote file succeeds and the commands fail, subsequent delivery attempts will try to do only the pre and post commands since the delivery of the actual file has already succeeded.
If Pre and Post commands are used
for Network or HTTP deliveries, the header will be considered
invalid, and the output document will be flushed.
Examples: FTP
Examples using Pre and Post commands |
|
Examples using Connection Open commands |
Examples using Pre and Post
commands
Simple file
101 <Header>
<DestinationFilename filename="remoteFilename.txt"/>
</Header>
Data
Files using all tags
A
101 <Header>
<PreCommands>
<PreCommand command="SITE Stats"/>
</PreCommands>
<DestinationFilename filename="remoteFilename.txt" rename="No"/>
<PostCommands>
<PostCommand command="SITE file=yes"/>
</PostCommands>
</Header>
B
101 <Header>
<PreCommands>
<PreCommand command="CWD subdirectory"/>
</PreCommands>
<DestinationFilename filename="DestinationFilename.txt" rename="yes"/>
<PostCommands>
<PostCommand command="CDUP"/>
</PostCommands>
</Header>
Data to be sent.
Examples using Connection Open commands
This example will force the connection to close after the delivery has been completed.
<DestinationFilename
filename="FTP_O_RemoteFilename230.txt"
rename="Yes"
overrideKeepConnectionOpen="YES"
keepConnectionOpen="No"/>
Document Delivery technical notes. |