For |
Broadcast (Order Execution Mgt) Project |
|||
Purpose |
Determines what Broadcast will do when there is a data fetch error. Broadcast does the following based on whether you disable or enable BCO_DATA_FETCH_ERROR. |
|||
|
Disable BCO_DATA_FETCH_ERROR |
|||
|
Even when there is a data fetch error Jobs are sent to the device. An alarm and log are generated. |
|||
|
|
Note: In a normal scenario (BCO_DATA_FETCH_ERROR is disabled or enabled) the following occurs. |
||
|
|
Whether or not there is an error, W or A is added to the filename, as follows. |
||
|
|
|
WYSIWYG |
W is added. |
|
|
|
Example 0001094033735734;W;111-11;111-11;All in One-SOLVE_PRT_EXPRT;221;YANE;111-11;.cwf |
|
|
|
|
ASCII |
A is added. |
|
|
|
Example 0001094033735734;A;111-11;111-11;All in One-SOLVE_PRT_EXPRT;221;YANE;111-11;.caf |
|
|
Enable BCO_DATA_FETCH_ERROR |
|||
|
When there is a data fetch error the following occurs. |
|||
|
Jobs: Do not go to the device. A zero is added to the filename, before the W or A. (W and A are described in the Disable BCO_DATA_FETCH_ERROR section.) |
|||
|
|
|
WYSIWYG |
0 is added before the W. |
|
|
|
Example 0001094033735734;0W;111-11;111-11;All in One-SOLVE_PRT_EXPRT;221;YANE;111-11;.cwf |
|
|
|
|
ASCII |
0 is added before the A. |
|
|
|
Example 0001094033735734;0A;111-11;111-11;All in One-SOLVE_PRT_EXPRT;221;YANE;111-11;.caf |
|
|
Stay in the active folder of the device. This does not allow any of the subsequent jobs to be sent to the device. A log is generated in the cor log. An alarm is generated. The user must: 1. Open the file manually 2. Enter correct data for the objects / fields which had data fetch error 3. Rename the file by removing the appended 0, Result: the jobs will start being posted to the device. |
|||
Value |
0 |
(Or any value other than 1) Disabled |
||
|
1 |
Enabled |
||
Default Value |
0 |
Disabled |
||
|
|
|
|
|
Global parameters. |