Sample .INI File

; Device level parameters

; UseTheseDomainSizes - When enabled (=1), use the sizes defined in the INI

;                        to defined the memory sizes for each domain

;                       When disabled (=0), for STAT_PLC, use the following

;                        defaults:

;                           Max Coils :       32768 elements

;                           Max Input Status: 32768 elements

;                           Max Input Regs:   16384 elements

;                           Max Holding Regs: 16384 elements

;                        All other memory types are 0 elements

;;                        For all other device models, the device communication

;                        interface will attempt to size the memory

;                        The default value is 0

;

; UseCounts - When enabled (=1), indicates sizes are in elements

;             When disabled (=0) indicates sizes are in bytes

;

;             Default value is 0

;

; ConservesConn - When enabled (=1), indicates that it is normal for the device

;                 to close the connection (typically based on inactivity).  The

;                 device communication interface will not assume that the

;                 device is down unless it is unable to create a connection and

;                 get a response when it attempts the current scheduled

;                 operation to retrieve data from the device or modify data.

;

;                 When disabled (=0), indicates that a termination of the

;                 connection between the device communication interface and

;                 the device will cause the device communication interface to

;                 assume that the connection is down and terminate the

;                 connection

;

;                 Default value is 0.

;

; ConnSecondary - When Enabled (=1), in a Host Redundant environment,

;                 the device communciation interface will attempt to

;                 maintain a connection with the device on the acting

;                 secondary. 

;

;                 When Disabled(=0), in a Host Redundant environment,

;                 the device communication interface will terminate its

;                 connection to the device when transitioning to the

;                 secondary.

;

;                Default value is 1.

;

; OneCoilWrite - When enabled (=1) use Function 5 to write single coils

;                When disabled (=0) use Function 15 to write single coils

;

;                VersaMax ENIU, VersaPoint ENIU and Modicon 484's ignore this

;                parameter.

;

;OneRegiserWrite - When enabled (=1) use Function 6 to write single holding registers

;                  When disabled (=0) use Function 16 to write single holding registers

;

;                  VersaMax ENIU, VersaPoint ENIU and Modicon 484's ignore this

;                  parameter.

;

[DEVICE1]

UseTheseDomainSizes=1

UseCounts=0

OneCoilWrite=0

OneRegWrite=0

ConservesConn=1

ConnSecondary=0

COILS=65535

DISC INPUTS=65535

INPUT REG.=65535

HOLDING REG.=65535

GEN REF FILE1=0

GEN REF FILE2=0

GEN REF FILE3=0

GEN REF FILE4=0

GEN REF FILE5=0

GEN REF FILE6=0

GEN REF FILE7=0

GEN REF FILE8=0

GEN REF FILE9=0

GEN REF FILE10=0

DP_INPUT REG.=0

DP_HOLDING REG.=0

 

[DEVICE2]

UseTheseDomainSizes=1

UseCounts=0

OneCoilWrite=0

OneRegWrite=0

ConservesConn=1

ConnSecondary=0

COILS=65535

DISC INPUTS=65535

INPUT REG.=65535

HOLDING REG.=65535

GEN REF FILE1=0

GEN REF FILE2=0

GEN REF FILE3=0

GEN REF FILE4=0

GEN REF FILE5=0

GEN REF FILE6=0

GEN REF FILE7=0

GEN REF FILE8=0

GEN REF FILE9=0

GEN REF FILE10=0

DP_INPUT REG.=0

DP_HOLDING REG.=0

More information

Step 1.2.3.2. Configure INI Parameters.