This subroutine gets the response to a specific request. If the call is successful, Point Management returns the following:
Pointers to the Shopping List and
point associated with the request;
A status;
A value.
If no response is available for the specified request, this function returns COR_WARNING.
Syntax
int PTMAP_get_req (req_adr, sl_adr, point_adr,
rsp_type, rsp_stat, rsp_ptr,
retstat)
PTMAP_ADDR *req_adr;
PTMAP_ADDR *sl_adr;
PTMAP_ADDR *point_adr;
int *rsp_type;
COR_STATUS *rsp_stat;
PTM_RSP **rsp_ptr;
COR_STATUS *retstat;
Input Arguments
req_adr |
Pointer to the request. |
Output Arguments
sl_adr |
Pointer to the Shopping List associated with this request. |
Point_adr |
Pointer to point associated with this request. |
Rsp_type |
Request type (such as, PTM_ONCHANGE or PTM_SNAPSHOT). |
Rsp_stat |
Status of the response: COR_SUCCESS, COR_WARNING, or COR_FAILURE. |
Rsp_ptr |
Pointer to a response structure. |
Retstat |
Pointer to status structure. The following errors may be returned (see Appendix A for an explanation of this code): |
|
PTMAP_ADR_PTR_NULL |
|
PTMAP_REQ_ADR_NULL |
|
PTMAP_REQ_ADR_NOTF |
|
PTMAP_SEQ_NUM_MISMATCH |
|
The following warnings may be returned: |
|
PTMAP_NO_RSP_RCV |
|
PTMAP_RCV_QUE_ERR |
Return Value
The contents of retstat.status.
Point Management API subroutines. |