A typical Status Log entry looks like:
The following fields have special meaning for Smarteye reader errors
Process |
The port used to communicate with the reader |
Code |
The error code returned by the Smarteye Electronic Assembly. Refer to the Smarteye Electronic Assembly User Manual for help in interpreting this code. |
|
This same code appears in a NUM format error point configured for the reader. |
Reference |
The octal address of the Smarteye reader. The first two digits indicate the Smarteye Electronic Assembly, and the last digit is the reader number on that SEA. For example, a reference of 245 would indicate an error on reader 5 of the SEA at address 240. |
Error Message |
This is the message that appears in a STR format error point configured for the reader. |
Smarteye reader errors. |