Right-click Decisions routing control object folder, e.g. under BCO_RCO1.
Select New Decision from the popup menu.
Configure the Decision pane as follows.
|
Field |
Description |
A |
Decision Name |
Name of the new decision. |
B |
Source |
Region that is the source of the order item. |
C |
Destination |
Region that is the destination of the order item. |
Right-click the Output Logic Module field.
button to the right of theSelect New on the popup menu.
An Output Logic Wizard opens.
Enter a name, e.g. Send W forms.
Enter a description, e.g. Send WYSIWYG Forms to printer.
Create a Get WYSIWYG Form function block as follows.
Click the Function Blocks box toolbar.
button on the
The Select a Function Block browser opens.
Expand the BCO folder.
Select Get WYSIWYG Form.
Click
.A Get WYSIWYG Form dialog box opens.
Fill in the fields as follows.
Field |
Description |
WYSIWYG Form Name |
The name of the WYSIWYG form that is merged
with the data that has been fetched, |
Region ID |
ID of the region where the item is
located, |
Region Location |
Location of the item in the selected region. |
Item Class |
Class of the item, e.g. ORDER. Note: If Item Class is blank all items in the selected Region, Region Location and of the selected Item Type will be broadcast. |
Item Type |
Type of the item, e.g. PC ORDER. Note: If Item Type is blank all items in the selected Region, Region Location and of the selected item class will be broadcast. |
Click
.Get WYSIWYG Form displays in the Function Blocks list.
Create a Send WYSIWYG Form function block as follows.
Click the Function Blocks box toolbar.
button on theThe Select a Function Block browser opens.
Expand the BCO folder.
Select Send Form to Device.
Click
.A Send Form to Device dialog box opens.
Fill in the fields as follows.
Note: Complete details are available in the Send Form to Device function block description.
Field |
Description |
Device Group |
Device group to which Broadcast sends the data. The device group includes a primary and, optionally, a secondary computer. |
Priority |
The order in which the form should be broadcast relative to other forms in the queue. Note: If the user does not specify any job priority the default priority will be used to put the job in the device queue. Default priority is by broadcast type. Accepted values: 0-99 Highest priority: 99 |
Status Point Id |
The status point must:
A status point get the statuses of broadcast; the point can be used in CIMPLICITY Screens for monitoring purposes. Statuses that are updated to this status point are:
Where: 1 = Success 2 = Failure |
Click
.Get WYSIWYG Form and Send WYSIWYG Form display in the Function Blocks list.
Add any other RCO function blocks that you want to include in the OLM.
Click
.Click
to close the Output Logic Wizard.