In Constructor
Object Instance:1.
Install path:C:\Program Files\GE Fanuc\Proficy CIMPLICITY\
In CreateMemoryMapFile:
File Path:D:\CimPE\examples\HMI\Yane\rco\cma.sta
The Return Code for CMA file: 183
Out CreateMemoryMapFile:
In CreateMemoryMapFile:
File Path:D:\CimPE\examples\HMI\Yane\rco\DeviceList.sta
The Return Code for CMA file: 183
Out CreateMemoryMapFile:
In CreateMemoryMapFile:
File Path:D:\CimPE\examples\HMI\Yane\rco\seqnum.sta
The Return Code for CMA file: 183
Out CreateMemoryMapFile:
D:\CimPE\examples\HMI\Yane\CIMForms\WYSIWYGForms\prod\Uticor.cwf
In SetRCOScriptName
Out SetRCOScriptName
In SetDevice
In ReadCMA
FaultDevices:GRP1:FINEPRINT1:FINEPRINT2:0:0:3:2:$MAC_FR;GRP2:GENERIC / TEXT ONLY:GENERIC / TEXT ONLY (COPY
2):0:0:3:1:$SYSTEM;GRP3:VINAY:PRINT1:0:0:2:1:$SYSTEM;
Out ReadCMAData
In WYSIWYG_Send_Device
After CoCreate
Load Form success
In GenFld
c:\Program Files\GE Fanuc\Proficy CIMPLICITY\
In QUERY EXT_TRACKER_ATTRIBUTE
In ReadCMA
FaultDevices:GRP1:FINEPRINT1:FINEPRINT2:0:0:3:2:$MAC_FR;GRP2:GENERIC / TEXT ONLY:GENERIC / TEXT ONLY (COPY
2):0:0:3:1:$SYSTEM;GRP3:VINAY:PRINT1:0:0:2:1:$SYSTEM;
Out ReadCMAData
In ReadCMA
FaultDevices:GRP1:0:1;
Out ReadCMAData
In UpdateSeqNumNStat
SEQNUM Data in File:GRP1:0:1;
Modify - Old Token
Out UpdateSeqNumNStat
JobName:0001087203094343;W;---;---;---;---;---;---;.cwf
In GetPathToStore
c:\Program Files\GE Fanuc\Proficy CIMPLICITY\rco\spoollocation.txt
Merged Data:
Saved Data
In UpdateDevList
Out UpdateDevList
Error in WYSIWYG Fetch N Merge.
Out WYSIWYG_PostToDevice
WYSIWYG Broadcast Success.
In SetRCOScriptName
Out SetRCOScriptName
In SetDevice
In ReadCMA
FaultDevices:GRP1:FINEPRINT1:FINEPRINT2:0:0:3:2:$MAC_FR;GRP2:GENERIC / TEXT ONLY:GENERIC / TEXT ONLY (COPY
2):0:0:3:1:$SYSTEM;GRP3:VINAY:PRINT1:0:0:2:1:$SYSTEM;
Out ReadCMAData
In FetchNMerge
In GenFld
d:\CIMPLICITY\HMI\
In QUERY EXT_TRACKER_ATTRIBUTE
In Parser
ASCII file opened
D:\CimPE\examples\HMI\Yane\CimForms\ASCIIForms\Prod\All in One-SOLVE_PRT_EXPRT.caf
content:ASCIICH 13
content:TEXT "Tracker Attributes"
content:ASCIICH 13
content:TEXT "~~~~~~~~~~~~~~~~~"
content:TEXT "ATT1:"
content:PRTATTR ATT1
content:ASCIICH 13
content:TEXT "ATT2:"
content:PRTATTR ATT2
content:ASCIICH 13
content:TEXT "ATT3:"
content:PRTATTR ATT3
content:ASCIICH 13
content:TEXT "ATT4:"
content:PRTATTR ATT4
content:ASCIICH 13
content:TEXT "ATT5:"
content:PRTATTR ATT5
content:ASCIICH 13
content:TEXT "ATT6:"
content:PRTATTR ATT6
content:ASCIICH 13
content:ASCIICH 13
content:ASCIICH 13
content:TEXT "Tracker EXATTributes"
content:ASCIICH 13
content:TEXT "~~~~~~~~~~~~~~~~~~~~"
content:ASCIICH 13
content:TEXT "EXATT1:"
content:PRTEXATTR EXATT1
content:ASCIICH 13
content:TEXT "EXATT2:"
content:PRTEXATTR EXATT2
content:ASCIICH 13
content:TEXT "EXATT3:"
content:PRTEXATTR EXATT3
content:ASCIICH 13
content:TEXT "EXATT4:"
content:PRTEXATTR EXATT4
content:ASCIICH 13
content:TEXT "EXATT5:"
content:PRTEXATTR EXATT5
content:ASCIICH 13
content:TEXT "EXATT6:"
content:PRTEXATTR EXATT6
content:ASCIICH 13
content:ASCIICH 13
content:ASCIICH 13
content:TEXT "SOLVES Attributes"
content:ASCIICH 13
content:TEXT "~~~~~~~~~~~~~~~~~"
content:TEXT "BIt_VAR.Bit :"
content:SOLVE $SOLVE122$
In QUERY SOLVE
In QUERY SOLVE
content:ASCIICH 13
content:TEXT "AUTO_GEAR.GEAR :"
content:SOLVE $COM1$
In QUERY SOLVE
In QUERY SOLVE
content:ASCIICH 13
content:TEXT "BodyIDs.CheckDigit :"
content:SOLVE $Check Digit$
In QUERY SOLVE
In QUERY SOLVE
content:ASCIICH 13
content:TEXT "GEARL_EVEL.GEAR COUNT :"
content:SOLVE $C8$
In QUERY SOLVE
In QUERY SOLVE
content:ASCIICH 13
content:TEXT "ENGINE.V-Cylinders :"
content:SOLVE $C7$
In QUERY SOLVE
In QUERY SOLVE
content:ASCIICH 13
content:TEXT "Crank.Crk1_2 :"
content:SOLVE $C6$
In QUERY SOLVE
In QUERY SOLVE
content:ASCIICH 13
content:TEXT "COLOR.COLOR :"
content:SOLVE COLOR.COLOR
In QUERY SOLVE
In QUERY SOLVE
content:ASCIICH 13
content:TEXT "END."
content:
Merged Data: Tracker Attributes~~~~~~~~~~~~~~~~~ATT1:111ATT2:222ATT3:333ATT4:444ATT5:555ATT6:666
Tracker EXATTributes~~~~~~~~~~~~~~~~~~~~EXATT1:EX111EXATT2:EX222EXATT3:EX333EXATT4:---EXATT5:---E
XATT6:---SOLVES Attributes~~~~~~~~~~~~~~~~~BIt_VAR.Bit :---AUTO_GEAR.GEAR :---BodyIDs.CheckDigit :---G
EARL_EVEL.GEAR COUNT :---ENGINE.V-Cylinders :---Crank.Crk1_2 :---COLOR.COLOR :---END.
In PostToDevice
In GetPathToStore
d:\CIMPLICITY\HMI\rco\spoollocation.txt
Directory Path: C:\TEMP\IBC1\YANE\ACTIVE\FINEPRINT1
In UpdateDevList
Out UpdateDevList
Saved Data - Successfuly
LastErrorCode:135.
Out PostToDevice
ASCII Broadcast Success.
In Destructor
BcoComp |