Log/alarms configuration files. |
|
Row format in the configuration files |
|
Device pause/offline. |
Log/alarms configuration files
Configuration files for log/alarms are:
File |
Configurationfor: |
Printer_AlrNLogConfig.csv |
Errors on the Printer. |
Job_AlrNLogConfig.csv |
Errors in individual jobs. |
The two configuration files are located in the [CIMPLICITY Install]\RCO directory.
Row format in the configuration files
Each row in the configuration file has the following data:
|ErrorCode|Log-0/Alarm-1/Both-2|DFO-1|Message|ErrorCodeInHex
Where elements are:
Element |
Description |
|
First |
ErrorCode |
Indicates an error in the printer/job. |
Second |
Log-0 |
Log a particular error. |
|
Alarm-1 |
Generate an alarm for the error. |
|
Both-2 |
Log an error and generate an alarm. |
|
DFO-1 |
No alarming or logging |
Third |
Message |
Actual message when the corresponding error occurs. The message:
Recommendation: Keep the default settings. |
Fourth |
ErrorCodeInHex |
Hex code returned by the printer/job. |
|
1 |
Perform automatic device fail over. |
|
0 |
Do not perform automatic device fail over. |
Note: The printer_alrnlogConfig.csv and job_alrnlogConfig.csv files are available in the
...<CIMPLICITY install>\/rco
folder
Example
1|2|1|PRINTER_STATUS_PAUSED|0x00000001
Device Pause/Offline
The following happens when a user pauses the device or sets it to off line.
Pause/Offline |
Result |
Pause |
Logging and/or alarms respond immediately. |
Offline |
The status is not updated immediately. It will take a noticeable period of time to respond; the behavior of different devices will differ for the same error condition. As a result, you need to do the configuration settings. Currently the:
|
Broadcast troubleshooting. |