Log/Alarms Files Configuration

Log/alarms configuration files.

Row format in the configuration files

Device pause/offline.

Log/alarms configuration files

  1. Configuration files for log/alarms are:

File

Configurationfor:

Printer_AlrNLogConfig.csv

Errors on the Printer.

Job_AlrNLogConfig.csv

Errors in individual jobs.

  1. The two configuration files are located in the [CIMPLICITY Install]\RCO directory.

Row format in the configuration files

Each row in the configuration file has the following data:

|ErrorCode|Log-0/Alarm-1/Both-2|DFO-1|Message|ErrorCodeInHex

Where elements are:

Element

Description

First

ErrorCode

Indicates an error in the printer/job. 

Second

Log-0

Log a particular error.

 

Alarm-1

Generate an alarm for the error.

 

Both-2

Log an error and generate an alarm.

 

DFO-1

No alarming or logging

Third

Message

Actual message when the corresponding error occurs.

The message:

Is seen in the log or alarm based on the user setting

Provides a description of the error at the printer or job

Recommendation: Keep the default settings.

Fourth

ErrorCodeInHex

Hex code returned by the printer/job.

 

1

Perform automatic device fail over.

 

0

Do not perform automatic device fail over.

Note: The printer_alrnlogConfig.csv and job_alrnlogConfig.csv files are available in the ...<CIMPLICITY install>\/rco folder

Example

1|2|1|PRINTER_STATUS_PAUSED|0x00000001

Device Pause/Offline

The following happens when a user pauses the device or sets it to off line.

Pause/Offline

Result

Pause

Logging and/or alarms  respond immediately.

Offline

The status is not updated immediately.

It will take a noticeable period of time to respond; the behavior of different devices will differ for the same error condition.

As a result, you need to do the configuration settings.

Currently the:

Error Configuration setting applies to all the printers/devices.

Setting is common for all Broadcast projects on a system; it is not project specific.

More information