Error codes Returned by Production Tracking

The following error codes are returned by the Production Tracking Application Interface:

Number

Defined Constant

Description

11401

PRTI_FILE_READ_ERR

Error reading configuration file:

11402

PRTI_FILE_OPEN_ERR

Error opening one of the configuration files

11403

PRTI_SVC_DEF_MISSING

Undefined Service in file: <filename>

11404

PRTI_REG_DEF_MISSING

Undefined Region in file: <filename>

11405

PRTI_GRP_DEF_MISSING

Undefined Group in file: <filename>

11406

PRTI_XLATE_ERR

Error in ipc_xlate getting physical addr of: <address>

11407

PRTI_AUX_NAM_ERR

Error in ipc_aux_nam

11408

PRTI_ADD_PORT_ERR

Error in ipc_add_port

11409

PRTI_READ_PORT_ERR

Error in ipc_read_port

11410

PRTI_WRITE_PORT_ERR

Error in ipc_write_port

11411

PRTI_MF_INIT_ERR

Error initializing segment

11412

PRTI_CRESEG_ERR

Error creating segment

11413

PRTI_BAD_MSG

Error in segment

11414

PRTI_NOT_STATUS_SEG

Expected STATUS_SEG as response, rcvd:

11415

PRTI_EXTRA_SEGS

Ignored extra segments after STATUS_SEG or END_SEG

11416

PRTI_UNEXPECTED_SEG

Unexpected segment type: svc: <filename>

11417

PRTI_UNEXPECTED_SEG_TYPE

Unexpected segment type from PRT_DS:

11418

PRTI_ITEM_TYPE_NDEF

Item type identifier not valid:

11419

PRTI_ITEM_TYPE_NULL

Item type identifier NULL

11420

PRTI_NUM_ATTS_INVALID

Invalid number of item attributes specified

11421

PRTI_REG_ID_NDEF

Region identifier not valid:

11422

PRTI_REG_ID_NULL

Region identifier NULL

11423

PRTI_GRP_ID_NDEF

Group identifier not valid:

11424

PRTI_GRP_ID_NULL

Group identifier NULL

11425

PRTI_SVC_ID_NDEF

PRT service identifier not valid:

11426

PRTI_SVC_ID_NULL

PRT service identifier NULL

11427

PRTI_NS_EXT_PROC_INVALID

ext_proc_flag set for non-serialized item

11428

PRTI_SER_NO_ID

Serialized item missing both item id and reference id

11429

PRTI_NON_SER_ID

Non-serialized item has item id or reference id

11430

PRTI_INVALID_TRK_TYPE

Invalid Tracking Type (not SERIALIZED/NON_SERIALIZED)

11431

PRTI_INVALID_REG_LOC

Invalid region location

11432

PRTI_EXT_HOLD_NO_GRP

External hold specified without Group ID

11433

PRTI_EXT_HOLD_NON_SER

External hold specified for non-serialized item

11434

PRTI_INT_HOLD_NO_REASON

Internal hold specified without reason

11435

PRTI_REG_NOT_IN_GRP

Region not in group specified

11436

PRTI_REG_NOT_IN_SVC

Region not managed by service specified

11437

PRTI_GRP_NOT_IN_SVC

Group ID inconsistent with service specified

11438

PRTI_NO_DEL_SUCCESSES

No deletes successful to any PRT services

11439

PRTI_INVALID_DEST

Destination region is invalid for item of this type

11440

PRTI_NO_SUCH_ROUTE

No route exists between src: <region> dest: <region>

11441

PRTI_INVALID_ROUTE

Invalid route (%.15s->%.15s) for item type <item type>

11442

PRTI_SER_PARENT

Parent ID specified for serialized item

11443

PRTI_EXT_HOLD_NO_REASON

Group hold specified without reason

11444

PRTI_ROUTE_NDEF

Non-exist. route in PRT_INV_TYPE, src: <region> dest: <region>

11445

PRTI_INV_EXPLICIT_ROUTE

Can't deny explicit item-route, src: <region> dest: <region>

11446

PRTI_NO_TYPE_FOR_ROUTE

Denied type not on route, src: <region> dest: <region> type: <item type>

11447

PRTI_NOTHING_PENDING

No requests pending

11448

PRTI_CFG_NO_ROUTE

Route has no source and no destination region

11449

PRTI_EF_CHECK_ERR

Error checking event flag

11450

PRTI_ITEM_NOT_FOUND

Item not found

11451

PRTI_ITEM_NOT_FOUND_INC_SRCH

Item not found: some service(s) down

11452

PRTI_TOO_MANY_REQ

Total number in list less than number requested

11453

PRTI_UNKNOWN_INIT_SRC

MF_INIT segment received from unknown service

11454

PRTI_NO_SRC_OR_DEST

Route has no source and no destination region

11455

PRTI_NO_SVC_IMPLIED

No service specified (via svc_id/group_id/region_id)

11456

PRTI_BAD_SERVER_RESPONSE

PRT Data Server returned bad/error response

11457

PRTI_NO_MORE_ITEMS

No more items available

11458

PRTI_BAD_POINTER

Pointer to data structure is NULL

11459

PRTI_UNKNOWN_RESPONDER

Response received from unknown service

11460

PRTI_EMPTY_FILE

Configuration file has no records:

11461

PRTI_BAD_SVC_NAME

Bad service name (no underscore):

11462

PRTI_PARTNER_DEAD

Partner dead

11463

PRTI_DG_BUF_FULL

Datagram buffer full

11464

PRTI_NO_SEGS_RCVD

No segments received into datagram buffer

11465

PRTI_API_CANT_RCV

PRT Application not initialized to receive asynch messages

11466

PRTI_INIT_MSG_RCVD

Init segment received from Data Collector

11467

PRTI_PROC_NOT_CONFIGURED

Process is not configured as network process

11468

PRTI_NOT_ALL_SVCS_RESPONDED

Not all services responded

11469

PRTI_NON_SER_ATTS

Non-serialized item has attribute(s)

11470

PRTI_CANT_MOD_ITEM_REF_IDS

Can't modify both item & ref.ids

11471

PRTI_CANT_MOD_ITEM_WOUT_REF

Must specify ref. id to modify item id

11472

PRTI_REGION_NOT_IN_GROUP

Region <region> does not belong to any group

11473

PRTI_GROUP_HAS_NO_REGIONS

Group <group> does not 'own' any regions

11474

PRTI_REORD_NUM_TOO_BIG

element <element> bigger than

11475

PRTI_GRP_SPANS_SVCS

Can't put region %s in group %s (wrong service)

11476

PRTI_SVC_NOMATCH

No configured Services for the PRT System:

11477

PRTI_REGSVC_NOMATCH

No configured Regions for the PRT System:

11478

PRTI_BAD_ALLOC

Error allocating memory!

11479

PRTI_NULL_ITEMTYPE_LIST

Bad item type list.

More information

5. PRT validation and configuration.