Send WYSIWYG Form By Variable

(Available with Order Execution Mgt.)

Description

Send WYSIWYG Form By Variable specifies the device group for the form selected by Get WYSIWYG Form by Variable.

Send WYSIWYG Form By Variable should be used only with Get WYSIWYG Form by Variable.

Parameters

This function block has the following parameters:

Parameter

Description

Device Group

Device group to which Broadcast sends the data.

Status Point ID

Point to use to get the statuses of Broadcast. This point can be used in CIMPLICITY CimView screens for monitoring purposes.

The user must use a Point Array, as follows.

 

Type

STRING20

 

Number of elements

Greater than 2 times the maximum number of items that may be broadcast at a time for proper results.

 

The statuses that are updated to this status point are:

  1. Item Id Broadcast

  2. Success/Failure Of Broadcast.

 

 

1

Success

 

 

0

Failure

Print Copies

Number of copies of each form that should be printed.

 

Default

1

More information

BCO function block list.