Eliminate Decision by Attribute Attribute

Description

Eliminate Decision by Attribute Attribute eliminates a decision based on the comparison of two attribute values.

Parameters

This function block has the following parameters:

Parameter

Description

Decision ID

ID of decision to be eliminated.

Region ID

Region which contains the first item to compare.

Region Location

Location of first item in the region.

Item Class

Class of item to compare. Optional

Attribute ID

Attribute of first item to compare.

Start Character

Starting character of the attribute to be used.

Attribute Length

Specifies the number of characters in the attribute to compare.

Enter zero in both the Start Character and Attribute Length fields to use all characters.

Condition

Type of Comparison - Greater Than, Less Than, Equals.

Comparison

Specifies the comparison type – numeric, alphabetic.

Region ID

Region which contains the second item to compare.

Region Location

Location of second item in the region.

Item Class

Class of the second item.

Attribute ID

Attribute of second item to compare.

Start Character

Starting character of the attribute to be used.

Length

Number of characters to compare.

More information

Eliminate Decision by Attribute Attribute example.

Eliminate Decision by Attribute Attribute pseudo code.

Routing function blocks list.