Syntax
PrtRegion.DeleteItem regionLoc, disposition [, comment$]
Description
Deletes all items in a location whose number was defined as a parameter.
Parameter |
Description |
regionLoc |
Integer. The location of the item in the region. |
disposition |
Integer. The disposition of the deleted item. See table below. |
comment$ |
String. (Optional) - an optional comment to place in the PRT log. |
Disposition |
Description |
PRT_SCRAP |
Scrap the item. |
PRT_DELETE |
Delete the item. |
PRT_NO_CHECK_SCRAP |
Scrap the item overriding region locking status. |
PRT_NO_CHECK_DELETE |
Delete the item overriding region locking status. |
Example
Dim Region as new PrtRegion
Region.Id = "PRODUCTION"
Region.GetData
For i = Region.MaxLocation to 1 Step -1
Region.DeleteItem i, PRT_DELETE
Next i