Step 3. Select the RCO Database Connection Parameters

  1. Click Next in the POMS Wizard Destination dialog box.

The POMS Wizard RCO Database Connection Parameters dialog box opens.

  1. Provide the following data, as follows.

Specification

Description

Server

The node on which the SQL database is located.

Note: If you are using CIMPLICITY SQL, the server will have \CIMPLICITY in it's identification.

 

Opens Data Link Properties dialog box, in which you can find or set up the server if it is not already set up.

Note: Microsoft help is available for your configuration.

Database

The SQL database that will contain the Tracker RCO data.

Important: The RCO database requires SQL Server 2000 and service pack 2 for SQL Server 2000.

 

Create Database

If an RCO database does not exist:

  1. Enter a name in the Database field.

  2. Click Create Database.

The POMS Wizard will create a database with the name you entered. A message will tell you if the operation was successful.

Note: You cannot select an existing RCO database.

User ID

Login ID required to access the database.

Password

Password required to access the database.

  1. Click Test Connection.

A message tells you if the connection succeeded.

Result: The RCO database will be available for your project's RCO data. The Next button, which has been disabled, is enabled.

More information

About the POMS Wizard.