Data |
|
Description |
Allow |
||
P |
pKey |
bigint |
8 |
Region primary key. Internally used only |
|
|
|
regionID |
varchar |
16 |
Region unique ID. |
|
|
|
region_status |
int |
4 |
Region status word. |
|
|
|
tracking_type |
varchar |
16 |
Region tracking type. Types are:
|
|
|
|
region_type |
int |
4 |
Region sub type |
|
|
|
|
|
|
1 |
Normal |
|
|
|
|
|
2 |
Combine |
|
|
|
|
|
3 |
Disperse |
|
|
cfg_locations |
int |
4 |
Number of locations that are configured. |
|
|
|
cfg_items_per_location |
int |
4 |
Configured location capacity. |
|
|
|
cfg_item_capacity |
int |
4 |
Configured Item capacity The capacity is: cfg_locations*cfg_items_per_location |
|
|
|
alloc_locations |
int |
4 |
Number of locations allocated. The number can be up to: 2 x cfg_locations. |
|
|
|
int |
4 |
Number of Items allocated. The number is: alloc_locations*cfg_items_per_location |
|
||
|
total_items_in_region |
int |
4 |
Number of Items currently in the Region |
|
|
|
occupied_locations |
int |
4 |
Number of Locations occupied by at least 1 Item |
|
|
|
det_region_id |
varchar |
16 |
Recursive foreign Key to the TrkRegions table; identifies the Detainment Region for this Region |
|
|
|
auto_assoc_region |
bit |
1 |
Flag to indicate if this is an Auto Association Region |
|
|
|
tran_region_id |
varchar |
16 |
Recursive foreign Key to TrkRegions table; identifies the Transition Region for this Region. Important: tran-region_id is valid only for Shifting regions. |
|
|
|
total_items_exiting_region |
int |
4 |
Number of Items that have exited this Region |
|
|
|
total_items_to_repair |
int |
4 |
Number of Items that have exited this Region and been moved to Detainment. |
|
|
|
PRTC_VALSTATS_MODIFY_MASK |
int |
4 |
Internal validation statistics |
|
|
|
PRTC_VALSTATS_TOTAL_VALIDATIONS |
int |
4 |
Internal validation statistics |
|
|
|
PRTC_VALSTATS_INVALID_COUNT |
int |
4 |
Internal validation statistics |
|
|
|
PRTC_VALSTATS_TOTAL_INVALID |
int |
4 |
Internal validation statistics |
|
|
|
PRTC_VALSTATS_TOTAL_DBL_TRIGGER |
int |
4 |
Internal validation statistics |
|
|
|
PRTC_VALSTATS_TOTAL_MISMATCH |
int |
4 |
Internal validation statistics |
|
|
|
PRTC_VALSTATS_CONS_MISMATCH |
int |
4 |
Internal validation statistics |
|
|
|
PRTC_VALSTATS_TOTAL_NOREAD |
int |
4 |
Internal validation statistics |
|
|
|
PRTC_VALSTATS_CONS_NOREAD |
int |
4 |
Internal validation statistics |
|
|
|
[$timeStamp] |
datetime |
8 |
Datetime of last modification (Internal) |
|
P = Primary key
2. TADB SQL table structure overview. |