Using CitectSCADA > Defining and Drawing Graphics Pages > Understanding Object Types > Polygon Properties - Appearance (General)

Polygon Properties - Appearance (General)

Polygons have the following general appearance properties.

[Line] Width

The width of the outline of the polygon (in pixels). You can change the width by clicking the up and down arrows to the right of the field, or by entering another value in this field.

If you make the line more than 1 pixel wide, it needs to be solid.

[Line] Style

The outline style of the polygon. You can choose any one of the following line styles:

To change the style, choose the style you want from the menu to the right of this field.

[Line] Color

The outline color of the polygon.

[Fill] Filled

The Filled check box, determines whether the polygon will be filled with a color.

[Fill] Color

The color with which the polygon will be filled. The color that you select as your fill color here is static.

To specify a fill color that changes with runtime conditions, click the Fill tab. If you have enabled the Fill (Color) properties, be aware that the color you select here will override the OFF color for Fill Color (On/Off), the ABC color for Fill Color (Multi-state), Array Color 0 for Fill Color (Array), and the At minimum color for Fill Color (Gradient).

[Gradient] Color

Controls the color of the gradient fill between the fill color and the gradient color. This option is available only when the Filled and Gradient Fill check boxes are selected. The gradient is updated at runtime to reflect the gradient between the two colors selected. Gradient fills support flashing colors.

Gradients do not rotate with an object; for example, if an object contains a left-to-right gradient fill and is rotated 90 degrees (either at runtime or in Graphics Builder), the gradient is still left to right.

[Gradient] Direction

The direction to be used for the gradient color. Use the table below as a guide to choose the gradient color direction you want.


Gradient Color Direction

Left to Right

Right to Left

Top to Bottom

Bottom to Top

Horizontal Gradient to Middle

Horizontal Gradient from Middle

Vertical Gradient to Middle

Vertical Gradient from Middle

[Object type] Open

Defines the object as a polyline (the first point and the last point are not joined).

[Object type] Closed

Defines the object as a polygon (the first point and the last point are joined).

For help on the remaining properties tabs, see Defining Common Object Properties.