Home 
  
  
 Change View 
  
  
 Print 
  

DynProperties for subitem "State"

Reaction matrix state

Name Type Description
AllValues Long This property gets/sets the "Treat each change of value as new limit violation" setting of a state.
CaseSensitive Boolean This property gets/sets the "case sensitive" option of a string rema.
CheckArt Long This property gets/sets the limit definition (if a value can be greater, less, equal, any or in an area).
Color Long This property gets/sets the color of a state.
Counter Long This property gets/sets the counter of a state (in combination with an operations- and operation hours counter).
DelayTime Long
Function ZT_FUNCTION This property gets/sets the function which is connected to a state.
GruppeIdx Long This property gets/sets the alarm group of a state.
Hysterese Double This property gets/sets the "Threshold value" of a state.
KlasseIdx Long This property gets/sets the alarm class of a state.
ReaAlarm Double This property gets/sets the value at which the state should act.
Hint: Further information in help of "State" collection.
ReaAlarmBis Double This property gets/sets the upper value when an area is projected at a state.
Hint: Further information in help of "State" collection.
ReaStatusExt Long This property gets/sets the extended status bits (PN_BIT, WR-ACK, WR-SUC, BL_BIT, SB_BIT, NT_BIT, OV_BIT, SE_BIT) of a rema status.
Hint: Further information in help of "State" collection.
ReaStatusFlankeExt Long This property gets/sets the edge triggered additional state bits (PN_BIT, WR-ACK, WR-SUC, BL_BIT, SB_BIT, NT_BIT, OV_BIT, SE_BIT) in a MultiBinary rema.
Hint: Further information in help of "State" collection.
ReaStatusFlankeStd Long This property gets/sets the edge triggered standard state bits in a MultiBinary rema.
Hint: Further information in help of "State" collection.
ReaStatusMaskeExt Long This property gets/sets the additional status bits (PN_BIT, WR-ACK, WR-SUC, BL_BIT, SB_BIT, NT_BIT, OV_BIT, SE_BIT) of a rema status.
e.g. zRema.DynProperties("State[1].ReaStatusMaskeExt") = &H40 (PN_BIT)
Hint: Further information in help of "State" collection.
ReaStatusMaskeStd Long This property gets/sets the standard status bits of a rema status.
e.g. zRema.DynProperties("State[1].ReaStatusMaskeStd") = &H40000 (I-BIT)
Hint: Further information in help of "State" collection.
ReaStatusStd Long This property gets/sets the standard status bits of a rema status.
Hint: Further information in help of "State" collection.
ReaStringValue String This property gets/sets the condition string of a string rema.
ReaWert Long This property gets the binary combination of a Binary rema.
Hint: Further information in help of "State" collection.
ReaWertFlanke Long This property gets/sets the edge triggered binary combination of a MultiBinary rema.
Hint: Further information in help of "State" collection.
ReaWertMaske Long This property gets/sets the binary combination of a Binary rema.
Hint: Further information in help of "State" collection.
Status Long This property gets/sets the value (each option of a state has a perceived value) which describes a projected state.
Text String This property gets/sets the limit text of a state.
UserProperty1 String

User property 1

In the Runtime the user property defined here can be evaluated in a VBA macro.

Read more in the online manual

UserProperty2 String

User property 2

In the Runtime the user property defined here can be evaluated in a VBA macro.

Read more in the online manual

Wildcards Boolean This property gets/sets the "wildcard" option (limit string can have wildcards) of a string rema.