DynProperties for subitem "ChargeFilter"

Funktionsparameter Chargenfilter

Name Type Description
Archive String
Count Long Specifies how many last closed batches are displayed.

Hint: Only available, if DynProperty "LastCharge" is set to 1.
FilterActive Long Activates filter on batches, if set 1. Otherwise (0) the DynProperty settings for batch filtering will be ignored.
LastCharge Long If set to 1, the last (specified within DynProperty "Count") closed batches are displayed.

Otherwise (0) batches will be selected by the specified time limits.
Name String Batch name that should be filtered for. Default: "*" (All batches within the time limit)

List of batches: Batch1|Batch2

Hint: Only available, if DynProperty "LastCharge" is set to 0.
ResString String
TimeLimits Long Specifies the time limits for the batches:

0Outside: Batches that only lie partially within the time limit are fully enclosed.
1Inside: Batches that only lie partially within the time limit are not enclosed.
2From outside: Batches that started before the time limit are fully enclosed. Batches that end after the time limit are not enclosed.
3To outside: Batches that end after the time limit are fully enclosed. Batches that started before the time limit are not enclosed.
4Cut: Variables of batches that only partially lie within the time.

Hint: Only available, if DynProperty "LastCharge" is set to 0.