Applies To:
  • CitectSCADA 1.00, 1.01, 1.10, 1.11, 1.20, 2.00, 2.01

Question: I want to Install Citect on the local drive of all computers on my Network. Can I Install it on the file server and then install on the local computers without using the floppy disks? 

To install Citect onto a Network to allow installation on local drives:

1). Create a directory on the file server to hold the Citect install files. Eg F:\INSTALL.

2). Copy all of the Citect install disks (except for the demo) into this directory. (If you want to install the demo, create another directory and copy the demo. Eg F:\INSTALL\DEMO.)

3). Run SETUP.EXE in the F:\INSTALL directory. The setup program will install Citect and will prompt you to insert each disk. When prompted, enter the path to the files, eg F:\INSTALL.

4). To install the demo, create a new DEMO project and use 'Backup/Restore' to restore the Demo. Select 'Restore' , Disk Drive (*) Other and enter F:\INSTALL\DEMO.