Applies To:
  • CitectSCADA 5.00

I am trying to use the CTApi function ctCicode. However it is always returning FALSE. If I look at the returned string all is OK. The Online help says that for successful completion it should be returning TRUE. 

There is a problem with the CTApi function ctCicode in which it currently returns FALSE for successful completion and an error number when it has failed. It should, as stated in the Online help, return TRUE in all situations. Errors are returned via the return string. These are "Unknown Function" when you try and call an unknown function in Citect or the error number, as a string, returned from the Citect function if it was in error

CIT has confirmed this to be a problem in Citect for Windows versions 5.00. This problem has been fixed in version 5.00 Service Pack A.