Applies To: |
|
Summary: |
The ABB Advant Series of PLCs support a number of different protocols. What are these protocols, and does Citect support them? If so, how? |
Solution: | ||||||||||||||||||||||||||||||||
ABB Advant Controller 70
Advant Controller 70 is specifically designed for small PLC-type applications. Communication with Citect may be achieved through: - Modbus. See KB article Q2453. - Advant Fieldbus 100. Via ABB AF100 OPC-server. See KB article Q2632 ABB Advant Controller 110 Advant Controller 110 is a medium-sized, process controller offering control and communication functions. It is designed to suit a wide range of industrial applications. Communication with Citect may be achieved through: - Modbus. See KB article Q2453. - Advant Fieldbus 100. Via ABB AF100 OPC-server. See KB article Q2632. - 3964R. Via Citect SIEMENS protocol. ABB Advant Controller 160 Advant Controller 160 may be configured to include redundancy. Communication with Citect may be achieved through: - Modbus. See KB article Q2453. - Advant Fieldbus 100. Via ABB AF100 OPC-server. See KB article Q2632. - 3964R. Via Citect SIEMENS protocol. ABB Advant Controller 210 Advant Controller 210 is a controller specifically designed for small PLC-type applications. Communication with Citect may be achieved through: - Comli. Via the Citect COMLI protocol. Note: You must use the latest version of the Advant Controller Builder Software Version 1.1-24 or later. - 3964R. Via Citect SIEMENS protocol. ABB Advant Controller 250 Advant Controller 250 is a comprehensive process controller for medium to large size application Communication with Citect may be achieved through: - Comli. Via the Citect COMLI protocol. . Note: You must use the latest version of the Advant Controller Builder Software Version 1.1-24 or later. - 3964R. Via Citect SIEMENS protocol. - Sattbus. Via the Citect SATTBUS protocol. (To be released in the near future) ABB Advant Controller 410 Advant Controller 410 with Master software is a medium size process controller for binary, regulatory, and supervisory control. Communication with Citect may be achieved through: - GCOM. Via the Matrikon GCOM OPC-Server. - Advant Fieldbus 100. Via ABB AF100 OPC-server. See KB article Q2632 ABB Advant Controller 450 Advant Controller 450 with Master software is a high-end, high performance process controller for binary, regulatory, and supervisory control. Communication with Citect may be achieved through:
* These methods have not been tested with Citect. |
Keywords: |
DCS, AC70, AC110, AC160, AC210, AC250, AC410, AC450 |
Related Links
Attachments