Applies To:
  • CitectSCADA v7.10 spk 2
HF710SP246543 for CitectSCADA Version 7.10 Service Pack 2

This combined hotfix includes the following fixes:

Bug 42163 - Using Taginfo to test existence of tags before call super genies doesn't work for alarm tag properties
Bug 43872 - Cannot View Alarm Pens in Process Analyst if User does not have correct privilege
Bug 44100 - Acknowledged, cleared alarms are active on redundant server after startup and synchronisation
Bug 44162 - Citect communications can be lost/dropped/closed on a mal-functioning/overloaded/unreliable network
Bug 44505 - Alarm index file corruption occurred when removing and adding alarms and then restarting CitectSCADA
Bug 44586 - A popup window containing many symbol set array objects takes a long time to display due to memory leak
Bug 44678 - Alarm High value property is not being transmitted to the redundant alarm server
Bug 44982 - AlarmActive will always return 0 on start-up when running in multi-process mode
Bug 46110 - After upgraded to CitectSCADA 7.10 Service Pack 2, alarm tag property super genie assignments failed
Bug 46302 - Super Genie associations do not show up on popup window
Bug 46540 - The web client fails to start

Files Affected:
AlarmServer.dll                           copy to _ProgramFilesFolder_\Citect\CitectSCADA 7.10\Bin\AlarmServer.dll
CtRegion.dll                              copy to _ProgramFilesFolder_\Citect\CitectSCADA 7.10\Bin\CtRegion.dll
CtApi.dll                                 copy to _CommonFilesFolder_\Citect\CtApi.dll
CtApi.dll                                 copy to _ProgramFilesFolder_\Citect\CitectSCADA 7.10\Bin\CtApi.dll
RuntimeConfiguration.dll                  copy to _ProgramFilesFolder_\Citect\CitectSCADA 7.10\Bin\RuntimeConfiguration.dll
CTTAGDB.dll                               copy to _ProgramFilesFolder_\Citect\CitectSCADA 7.10\Bin\CTTAGDB.dll
Client.dll                                copy to _ProgramFilesFolder_\Citect\CitectSCADA 7.10\Bin\Client.dll
CtCmp32.exe                               copy to _ProgramFilesFolder_\Citect\CitectSCADA 7.10\Bin\CtCmp32.exe
CtBack32.exe                              copy to _ProgramFilesFolder_\Citect\CitectSCADA 7.10\Bin\CtBack32.exe
CtDraw32.exe                              copy to _ProgramFilesFolder_\Citect\CitectSCADA 7.10\Bin\CtDraw32.exe
CtEdit32.exe                              copy to _ProgramFilesFolder_\Citect\CitectSCADA 7.10\Bin\CtEdit32.exe
CtExplor.exe                              copy to _ProgramFilesFolder_\Citect\CitectSCADA 7.10\Bin\CtExplor.exe
CtIndex.dll                               copy to _ProgramFilesFolder_\Citect\CitectSCADA 7.10\Bin\CtIndex.dll
IoServer.dll                              copy to _ProgramFilesFolder_\Citect\CitectSCADA 7.10\Bin\IoServer.dll
CiTrendArchiveFileOffset.dll              copy to _CommonFilesFolder_\Citect\CiTrendArchiveFileOffset.dll
CiTrendArchiveFileOffset8Byte.dll         copy to _CommonFilesFolder_\Citect\CiTrendArchiveFileOffset8Byte.dll
CiTrendArchiveInterpolator.dll            copy to _CommonFilesFolder_\Citect\CiTrendArchiveInterpolator.dll
CiTrendManager.dll                        copy to _CommonFilesFolder_\Citect\CiTrendManager.dll
TrendServer.dll                           copy to _ProgramFilesFolder_\Citect\CitectSCADA 7.10\Bin\TrendServer.dll
ReIndex.exe                               copy to _ProgramFilesFolder_\Citect\CitectSCADA 7.10\Bin\ReIndex.exe     web client\server