12.4.15.18           GOTO URL=http://URL

Description:   Opens calls the URL or web page.  

Syntax:         GOTO URL=http://URL^target=name^replace=option^style=option^settings=option

                        GOTO URL=http://URL

                        GOTO URL=http://URL^target=name

 

Arguments:    URL or Web page address and options to adjust appearance of browser.  (NO BLANK SPACES)

Returns:        none

See Also:      

 

Examples:         GOTO URL=http://yahoo.com

GOTO URL=64.55.156.4^target=pop^height=200^top=20^width=400

Changes display to a new HTML or other Web Page.  If target is specified, opens in a new Web Browser pop-up window.  If named target is already open, then new URL is opened in existing target window.   Will open an IE browser regardless of default browser on PC (always opens Internet Explorer). IE 6.0, 7.0, or later must be installed on client PC. This is supported by Browser based clients and ViewDAQ.  If connecting to the same WebAccess project  and used from a Web Browser Client, the new window does not require a new login.  Used from ViewDAQ, a new user login to the WebAccess web browser client is required.  The delimiter is the carrot ^  typed by pressing Shift 6.

Arguments for GOTO URL

URL       Also known as a web address. Can be a URL, IP Address, name in Hosts file or Network  name. Can include options associated with the URL including ASP options and WebAccess options.
 example: GOTO URL=http://67.94.27.201

Target    Name defines a Target window name with feature options specified.  Can be any name.  Optional, if no name specified, will open a new window popup. If a window with same name is already open, loads URL document into the named window. Using a target window name allows use of CLOSEURL command.  The CLOSEURL command  requires a target window name. No target name is equivalent to _blank and will open new window that cannot be closed using CLOSEURL command. The default window names used by HTML code are not supported (_blank, _parent, _search, _self, _top, _media). NO BLANK SPACES.
Syntax: 
target=name
example: GOTO URL=http://67.94.27.201^target=pop

replace   Options are (yes=1 no=0). Replace History Entry. When the URL is loaded into same window, this BOOLEAN parameter specifies whether the URL creates a new entry or replaces current entry in the windows history list. Optional. NO BLANK SPACES. Boolean values accepted ( 0 1 yes no ).
Syntax: 
replace=Boolean
example: GOTO URL=http://67.94.27.201^target=pop^replace=1

style       Options 0,1,2. Window Title Bar options.  Similar to Display Groups in ViewDAQ.
 (0 = Overlapped Window with Title,  1= Popup with Title, 2 =Popup without Title) . The Popup windows do not have Minimize, Maximize or Close controls preventing user from easily closing, the window. NO BLANK SPACES. Style is a number between 0 and 2.
Syntax: 
style=number
example: GOTO URL=http://64.55.156.4^target=pop^style=2

 
settings for GOTO URL

These settings used to control window size and position.  They are similar to replace and style above. Each setting option is delimited with the carrot ^ (typed shift 6).  NO BLANK SPACES.

fullscreen

Display Browser in full-screen mode. The default is no. Use full-screen mode carefully because this mode hides the browser's title bar and menus. You should always provide a button or other clue to help the user close the window. ALT+F4 closes the new window. Boolean values accepted ( 0 1 yes no ).
Syntax: 
fullscreen=Boolean
example: GOTO URL=http://64.55.156.4^target=pop^fullscreen=yes

 

height    Height of the browser window, in pixels. The minimum value is 100.
Syntax:
  height=number
example: GOTO URL=http://64.55.156.4^target=pop^height=200^width=400

 

left          Left position of the browser window, in pixels. The value is relative to the upper -left corner of screen.
Syntax: 
left=number
example: GOTO URL=http://64.55.156.4^target=pop^height=200^width=400^left=20

location 

Display the address bar in web browser (URL input field). Default value is yes. Boolean values accepted ( 0 1 yes no ).
Syntax: 
location=Boolean
example: GOTO URL=http://67.94.27.201^target=pop^location=no

menubar

Display the menu bar in web browser (File Edit View Favorites Tools). Default value is yes. Boolean values accepted ( 0 1 yes no ).
Syntax: 
menubar=Boolean
example: GOTO URL=http://67.94.27.201^target=pop^location=0^menbar=0

resizable

Display the resize handles at the corners of the window. The default is yes.
Boolean
values accepted ( 0 1 yes no ).
Syntax: 
resizable=Boolean
example: GOTO URL=http://yahoo.com^target=pop^location=0^menbar=0^resizable=0

status     Display the status bar at bottom of browser window. The default is yes.
Boolean
values  ( 0 1 yes no ).
Syntax: 
status=Boolean
example: GOTO URL=http://yahoo.com^target=pop^menubar=0^status=0

titlebar   Display the title bar in web browser. This setting is ignored unless the calling application is an HTML application or a trusted dialog box. Default value is yes. Boolean values ( 0 1 yes no ).
Syntax: 
menubar=Boolean
example: GOTO URL=http://67.94.27.201^target=pop^titlebar=0

toolbar   Display the tool bar in web browser with the button BACK, FORWARD and STOP. Default value is yes. Boolean values ( 0 1 yes no ).
Syntax: 
toolbar=Boolean
example: GOTO URL=http://67.94.27.201^target=pop^toolbar=0

top           Top position of the browser window, in pixels. The value is relative to the upper -left corner of screen.
Syntax: 
top=number
example: GOTO URL=64.55.156.4^target=pop^height=200^width=400^left=20^top=20

width      Width of the browser window, in pixels. The minimum value is 100.
Syntax: 
top=number
example: GOTO URL=64.55.156.4^target=pop^height=200^left=20^top=20^width=400