Properties in the Time Component Configuration Dialog
Box: General Tab
Property
|
Description
|
Values
|
Name
|
Specifies a name for the Time Component
object that will identify it when its parameters are linked to
another object.
|
Any text or numbers.
|
Absolute
|
A specific time and/or date, such as
12:55:47 Aug 5, 2003. If the Start & End option is selected,
enter an End time, as well.
|
Start – select a start date and time from
the calendar, or place your cursor before the value you want to
change and use the Up or Down arrows on your keyboard.
Stop – select an end date and time from the
calendar or place your cursor before the value you want to change
and use the Up or Down arrows on your keyboard.
|
Relative
|
A relative or named time, such as 1 Hour Ago
or 30 Minutes Ago. If the Start & End option is selected, enter
an End time, as well.
|
Start – select from the list box. The
displayed start date/time below changes to reflect your
selection.
Stop – select from the list box. The
displayed stop date/time below changes to reflect your
selection.
NOTE: Specific
dates/times, such as Day Shift are defined in the Named Time
Editor.
|
Range
|
A time range, such as Last Hour or Q1.
|
Range – select from the list box. The
displayed Start and Stop date/time below changes to reflect your
selection. For example, if you select Last
Hour, the Start date/time changes to one hour before the
current time (relative option). If you select Q1, the Start and Stop date/time values change to the
first 3 months of the year (absolute option).
NOTE: Specific
dates/times, such as Day Shift are defined in the Named Time
Editor.
|
Start
|
Indicates that the start time only is
displayed when the date/time option is set as either Absolute or
Relative.
|
N/A
|
Start & End
|
Indicates that the start and end times are
displayed.
|
N/A
|
Combo Box
|
Indicates that the time component is
displayed as a combo box.
|
N/A
|
List Box
|
Indicates that the time component is
displayed as a list box. This option is not available if Absolute
is selected.
|
N/A
|
Show Update
Button
|
Indicates that the Update button will be
used on the Time Component object during run-time. The Update check
box is available only for the Absolute time options.
|
Selected – the Update button appears on the
Time Component.
Cleared – the Update button does not appear
on the Time Component.
|
Show Evaluate
Time
|
Indicates whether to show the evaluation
value. For example, if you have a relative time option set with the
value `1 Hour Ago', the calculated time and the `1 Hour Ago' value
will both appear. If Show Evaluate Time is not selected, the
calculated time only will appear. This check box is not available
if Absolute is selected.
|
Selected – the value by which the date/time
is derived is shown. This does not apply to the Absolute
option.
Cleared – the value by which the date/time
is derived is hidden. This does not apply to the Absolute
option.
|