Series 160i, 180i, and 210i CNCs have the following requirements and options.
Required Series 160i, 180i, and 210i Model A/B/P software. |
|
Required software and options. |
|
HSSB board options. |
|
Ethernet board options |
|
Optional software and options. |
Required Series 160i, 180i, and 210i - Model A/B/P Software
|
HSSB |
10MB Ethernet |
100MB Ethernet |
System 160i - MA |
B0F1-1 or later |
B0F1-23 or later |
B0F4-02 or later |
System 180i - MA |
BDF1-1 or later |
BDF1-23 or later |
BDF4-02 or later |
System 160i - TA |
B1F1-1 or later |
B1F1-22 or later |
B1F4-01 or later |
System 180i - TA |
BEF1-1 or later |
BEF1-22 or later |
BEF4-01 or later |
System 160i - LA |
B8F1-1 or later |
|
|
System 160i - WA |
B9F7-1 or later |
|
|
System 180i - WA |
B9F4-19 or later |
|
|
System 160i - MB |
B0H1-01 or later |
B0H1-01 or later |
B0H1-02 or later |
System 180i - MB |
BDH1-01 or later |
BDH1-01 or later |
BDH1-02 or later |
System 180i MB5 |
BDH5-01 or later |
BDH5-01 or later |
BDH5-02 or later |
System 160i - TB |
B1H1-01 or later |
B1H1-01 or later |
B1H1-03 or later |
System 180i - TB |
BEH1-01 or later |
BEH1-01 or later |
BEH1-03 or later |
System 160i - LB |
B8H1-01 or later |
B8H1-01 or later |
|
System 180i - WB |
|
|
|
System 160i - PB |
B7H1-01 or later |
B7H1-01 or later |
|
System 180i - PB |
B7H5-01 or later |
B7H5-01 or later |
|
System 210i -MA |
DDF1-1 or later |
DDF1-15 or later |
DDF4-02 or later |
System 210i - MB |
DDEH1-01 or later |
DDH1-01 or later |
DDH1-02 or later |
System 210i -TA |
DEF1-1 or later |
DEF1-15 or later |
DEF4-031 or later |
System 210i - TB |
DEH1-01 or later |
DEH1-01 or later |
DEH1-03 or later |
Boot 160i -MA |
60M3-5 or later |
60M3-5 or later |
60M3-5 or later |
Boot 180i -MA |
60M3-5 or later |
60M3-5 or later |
60M3-5 or later |
Boot 160i -TA |
60M3-5 or later |
60M3-5 or later |
60M3-5 or later |
Boot 180i -TA |
60M3-5 or later |
60M3-5 or later |
60M3-5 or later |
Boot 160i-LA |
60M3-5 or later |
60M3-5 or later |
60M3-5 or later |
Boot 160i-WA |
60M3-15 or later |
60M3-15 or later |
60M3-15 or later |
Boot 180i-WA |
60M3-15 or later |
60M3-15 or later |
60M3-15 or later |
Boot 160i - MB |
60M3-5 or later |
60M3-5 or later |
60M3-5 or later |
Boot 180i - MB |
60M3-5 or later |
60M3-5 or later |
60M3-5 or later |
Boot 160i - TB |
60M3-5 or later |
60M3-5 or later |
60M3-5 or later |
Boot 180i - TB |
60M3-5 or later |
60M3-5 or later |
60M3-5 or later |
Boot 160i - LB |
|
|
|
Boot 180i - WB |
|
|
|
Boot 160i - PB |
|
|
|
Boot 180i - PB |
|
|
|
Boot 210i MA |
60M3-5 or later |
60M3-5 or later |
60M3-5 or later |
Boot 210i - MB |
60M3-5 or later |
60M3-5 or later |
60M3-5 or later |
Boot 210i -TA |
60M3-5 or later |
60M3-5 or later |
60M3-5 or later |
Boot 210i - TB |
60M3-5 or later |
60M3-5 or later |
60M3-5 or later |
10MB Ethernet Executive |
N/A |
6561-15 |
N/A |
100MB Ethernet Executive |
N/A |
N/A |
6567-01 or later 656A-02 (Embedded for iB only) |
PMC Executive iA |
406A-01 or later |
406A-12 or later |
406A-12 or later |
PMC Executive iB |
406G-01/406H-01 or later |
406G-01/406H-01 or later |
406G-01/406H-01 or later |
Required Software and Options
Drivers & Library Option Bit |
A02B-0207-J800 |
Ethernet Option Bit |
A02B-xxx-S707 Where xxx is dependant on the CNC type. |
Important: Ethernet for iA requires both option bits. Ethernet for iB requires only Ethernet option. |
HSSB Board Options
HSSB Board |
A02B-0236-J200 (CNC Side) A20B-8001-0580/0581 (PC Side) |
HSSB Board |
A02B-0236-J202 (CNC Side) A20B-8001-0582/0583/960/961 (PC Side) |
Ethernet Board Options
Board |
Executive Series |
CNC Model |
A02B-0236-J293 |
6567 |
iA (LCD) |
A02B-0236-J140 |
6567 |
iA (LCD) |
A02B-0236-J145 |
6561 |
iA (LCD) |
A02B-0236-J292 |
6561 |
iA (LCD) |
A02B-0265-J293 |
6567 |
iA (SA) |
A02B-0265-J145 |
6561 |
iA (SA) |
A02B-0265-J291 |
6561 |
iA (SA) |
A02B-0265-J152 |
6561 |
iA (SA) |
A02B-0281-J145 |
6561 |
iB (LCD) |
A02B-0281-J292 |
6561 |
iB (LCD) |
A02B-0281-J293 |
6567 |
iB (LCD) |
A02B-0281-J146 |
6567 |
iB (LCD) |
A02B-0281-J148 |
6561 |
iB (SA) |
A02B-0281-J149 |
6567 |
iB (SA) |
A02B-0281-J298 |
6561 |
iB (SA) |
A02B-0281-J299 |
6567 |
iB (SA) |
A02B-0281-J158 |
6561 |
iB (SA) |
A02B-0281-J160 |
6561 |
iB (SA) |
A02B-0281-J161 |
6567 |
iB (SA) |
A02B-0281-J162 |
6567 |
iB (SA) |
Built-in Port |
656A |
iB (LCD & SA) |
Optional Software and Options
Basic Operation Package 1
(BOP)
Basic Operation Package Option Bit |
A02B-0207-J810 |
Software Operator Panel Option Bit |
A02B-0201-J960 |
Switch Option Bit |
A02B-0201-J961 |
Software Operator Panel General
Purpose
Switch Option Bit |
A02B-0201-J961 |
Parameters for Open Systems
Software
The recommended parameters for Drivers and Libraries are:
Parameter |
Setting |
Description |
0 Bit 0 |
0 |
TV check. |
3201 Bit 2 |
1 |
Deletes the existing program before downloading a new program. |
3201 Bit 6 |
1 |
M02, M30, and M99 is program end. |
GE Fanuc HSSB and Ethernet Control Requirements. |