Enter a name for the network delivery object in the New Document Delivery dialog box.
Click
.A Delivery Properties dialog box opens for the named delivery object.
Select FTP in the Delivery Type drop-down list.
Parameters for the FTP delivery type are as follows.
Parameter |
Value |
||||
The type of delivery object. Options are: |
|||||
|
NETWORK |
Mapped network deliveries. |
|||
|
FTP |
FTP deliveries (default-selected in this option). |
|||
|
HTTP |
HTTP deliveries. |
|||
CIMPLICITY Alarm that will be triggered if a delivery has failed the number of times specified in the Delivery Failure Count parameter. Note: A default alarm of $DOCUMENT_DELIVERY has been provided, but a custom alarm can be used. |
|||||
Number of times the delivery object will try to resend an output document before it gives up and flushes the file. |
|||||
Range |
0 through 999 or infinite. |
||||
Failures Before Alarm |
The number of times the delivery object needs to fail in order to generate the alarm. |
||||
|
Range |
0 through 1000 failures. |
|||
|
Note: A value of 0 means no alarm will be generated. |
||||
Time in seconds to wait before a retry will be attempted. |
|||||
|
Range |
1 through 1000 seconds |
|||
Determines how to handle the delivery when a remote file of the same name as the one to be delivered is encountered. Options are: |
|||||
|
OVERWRITE |
Overwrites the existing file. |
|||
APPEND |
Attempts to append the current file to the end of the existing file. |
||||
|
FAIL ON EXISTING |
Fails if the remote file exists. |
|||
Name of the directory on the remote machine to which the file will be copied. The parameter must show the path from the root directory. |
|||||
|
Character limit |
100 characters. |
|||
|
The Destination field supports forward slashes (UNIX). |
||||
When set to YES enables, auditing for this delivery object. |
|||||
|
YES |
Enables audit. |
|||
|
NO |
There will be no audit. |
|||
Server Name /IP Address |
The FTP server name, or IP Address. The FTP prefix is not required or accepted. |
||||
Time out period used during communications. |
|||||
Range |
100 to 600,000 ms (100 ms to 10 minutes). |
||||
The port number to be used. Tip: If you do not know the port number, enter 0 and the Document Delivery process will attempt to determine the correct port number. |
|||||
Time out period used during the connection process. |
|||||
|
Range |
100 to 600,000 ms (100 ms to 10 minutes). |
|||
Name of the user to log in. Note: If empty, the user name is anonymous. |
|||||
|
Maximum length |
20 characters. |
|||
Opens a Change Password dialog box in which you can enter a password that will be required for log in. |
|||||
|
|
||||
|
Password length |
Up to 127 characters. |
|||
|
|
||||
Options are: |
|||||
|
YES |
Delivery object will attempt to keep the FTP Connection open. |
|||
|
NO |
Delivery object will close the FTP Connection on completion of the delivery. |
|||
|
|
|
|
|
|
Step 5. Configure delivery objects. |