2. Legacy and Obsolete Features

Proficy HMI/SCADA CIMPLICITY 8.0 includes Legacy  and As-Is features to accommodate clients who are still using them from previously configured CIMPLICITY versions. This will give you time to upgrade your systems.

Legacy Features in Proficy HMI/SCADA CIMPLICITY version 8.0

Obsolete Features in Proficy HMI/SCADA CIMPLICITY version 8.0

As-Is Proficy HMI/SCADA CIMPLICITY version 8.0

Obsolete Features in Proficy HMI/SCADA CIMPLICITY version 7.5

Obsolete Features in Proficy HMI/SCADA CIMPLICITY version 7.0

Legacy Features in Proficy HMI/SCADA CIMPLICITY version 8.0

Legacy features support equipment that is obsolete or functionality that has been superseded by far more effective and efficient functionality. Therefore, these features will not be available in the next major CIMPLICITY release after version 8.0.

CIMPLICITY 8.0 offers and supports the current CIMPLICITY Pager option.

However, the version after CIMPLICITY 8.0 will offer a new Notification system that will provide increased flexibility and functionality.

In the CIMPLICITY release after v8.0, GE Fanuc:

Will provide a migration path for existing clients who wish to upgrade from the current Pager to the new system.

Will support the upgrade process

Will support the new system.

Will not support the current Pager system.

Obsolete Features in Proficy HMI/SCADA CIMPLICITY version 8.0

The following features are obsolete in Proficy HMI/SCADA CIMPLICITY version 8.0.

Tracker features

PRT_STANDBY process

Configurable Tracking Interface (CTI)

Microsoft SQL 2000 is not supported in CIMPLICITY 8.0

As-Is Proficy HMI/SCADA CIMPLICITY version 8.0

These features are not actively being developed or supported. It is recommended that you find alternative solutions.

DDE Client Communications (Local only)

Ethernet Global Data Service

Note: Ethernet Global Data Service cannot be used with Proficy Process Systems and the EGD OPC Server.

Series 90 TCP/IP Communications (Do not use with PPS or EGD

Obsolete Features in Proficy HMI/SCADA CIMPLICITY version 7.5

The following features are obsolete in Proficy HMI/SCADA CIMPLICITY version 7.5.

Allen-Bradley Data Highway Plus Communications

CIMPLICITY with CIMPLICITY Control

Data Highway Plus KT card configuration.

Modbus Plus Device Communications

Net DDE Communications.

Series 90 Redundancy

Windows 2000 is not supported in Proficy HMI/SCADA CIMPLICITY beginning with version 7.5.

Obsolete Features in Proficy HMI/SCADA CIMPLICITY version 7.0

The following features are obsolete in Proficy HMI/SCADA CIMPLICITY version 7.0.

APPLICOM Communications

CIMPLICITY HMI Gateway

CIMPLICITY HMI Web Data applet

Genius ISA Communications

This has been replaced with Genius PCI Communications.

Historical Data Analyzer

Seriplex Communications

Windows NT is not supported in Proficy HMI/SCADA CIMPLICITY beginning with version 7.0.