Proficy HMI/SCADA CIMPLICITY 8.0 includes Legacy and As-Is features to accommodate clients who are still using them from previously configured CIMPLICITY versions. This will give you time to upgrade your systems.
Legacy Features in Proficy HMI/SCADA CIMPLICITY version 8.0 |
|
Obsolete Features in Proficy HMI/SCADA CIMPLICITY version 8.0 |
|
As-Is Proficy HMI/SCADA CIMPLICITY version 8.0 |
|
Obsolete Features in Proficy HMI/SCADA CIMPLICITY version 7.5 |
|
Obsolete Features in Proficy HMI/SCADA CIMPLICITY version 7.0 |
Legacy Features in Proficy HMI/SCADA CIMPLICITY version 8.0
Legacy features support equipment that is obsolete or functionality that has been superseded by far more effective and efficient functionality. Therefore, these features will not be available in the next major CIMPLICITY release after version 8.0.
CIMPLICITY 8.0 offers and supports the current CIMPLICITY Pager option. However, the version after CIMPLICITY 8.0 will offer a new Notification system that will provide increased flexibility and functionality. In the CIMPLICITY release after v8.0, GE Fanuc:
|
Obsolete Features in Proficy HMI/SCADA CIMPLICITY version 8.0
The following features are obsolete in Proficy HMI/SCADA CIMPLICITY version 8.0.
Tracker features
PRT_STANDBY process
Configurable Tracking Interface
(CTI)
Microsoft SQL 2000 is not supported in CIMPLICITY 8.0
As-Is Proficy HMI/SCADA CIMPLICITY version 8.0
These features are not actively being developed or supported. It is recommended that you find alternative solutions.
DDE Client Communications (Local only) |
|
Ethernet Global Data Service Note: Ethernet Global Data Service cannot be used with Proficy Process Systems and the EGD OPC Server. |
|
Series 90 TCP/IP Communications (Do not use with PPS or EGD |
Obsolete Features in Proficy HMI/SCADA CIMPLICITY version 7.5
The following features are obsolete in Proficy HMI/SCADA CIMPLICITY version 7.5.
Allen-Bradley Data Highway Plus
Communications
CIMPLICITY with CIMPLICITY
Control
Data Highway Plus KT card
configuration.
Modbus Plus Device
Communications
Net DDE Communications.
Series 90 Redundancy
Windows 2000 is not supported in Proficy HMI/SCADA CIMPLICITY beginning with version 7.5.
Obsolete Features in Proficy HMI/SCADA CIMPLICITY version 7.0
The following features are obsolete in Proficy HMI/SCADA CIMPLICITY version 7.0.
APPLICOM Communications
CIMPLICITY HMI Gateway
CIMPLICITY HMI Web Data applet
Genius ISA Communications
This has been replaced with Genius PCI Communications.
Historical Data Analyzer
Seriplex Communications
Windows NT is not supported in Proficy HMI/SCADA CIMPLICITY beginning with version 7.0.