Click Out of Seq.
Out of Seq fields display at the bottom of the advanced PRT Region Configuration dialog box.
Configure the Out of Sequence fields, as follows.
Field |
Description |
|||
Detainment Region |
ID for the region to which items will be sent when they exceed the out of sequence limit. |
|||
OOS cycle |
Maximum number of items that are allowed to exit out of sequence from the region. |
|||
OOS Action |
Does one of the following: |
|||
|
|
|||
|
|
Detain |
Moves item to detainment region. |
|
|
|
Scrap |
Scraps (delete) item. |
|
|
|
Delay Detain |
Allows item to be in out-of-sequence condition using the OOS cycle count, and then move to the detainment region. |
|
|
|
Delay Scrap |
Allows item to be in out-of-sequence condition using the OOS cycle count, and then scrap (delete). |
|
|
|
Important: When the OOS cycle field is 0 with any the above options there is no tolerance in the region for out-of-sequence items. |
||
|
|
|
||
|
|
Blank (no entry)
|
Disable out-of-sequence. Used if the sequence of items entering a region is not important. |
|
|
|
Note: The OOS cycle field should be 0 for this option. |
Important
A Tracking Region may have one and
only one Detainment Region.
Multiple regions may utilize the
same Detainment Region.
When moving an item in either a
pooled or sequential region, if it is not the first item in that
region, all the items in prior locations are deleted.
This is because an action must be chosen.