Step 4. Configure Node_logproc

  1. Use the IDTPOP Utility to convert the file to ASCII-text using the text editor of your choice, e.g. Notepad.

  2. Add a line that contains the following fields.

node_id|process_id|image_name|20|1|1|80|50|50000|0|50|2000|100|50000|10|-

50|99|999|9999|-1

Field No.

Field Name

Description

Entry Example

0

node_id

Node name, always MASTER.

MASTER

1

process_id

The name of the process that the program will look to for data.

AMRP

2

image_name

The name of the executable image.
Configure as follows:

Directory_name:[exe]prt_inttest.exe

BSM_ROOT:[EXE]
AMRP.EXE

Use the default values for the remaining fields.

|20|1|1|80|50|50000|0|50|2000|100|50000|10|-50|99|999|9999|-1

Example

MASTER|AMRP|BSM_ROOT:[exe]amrp.exe|20|1|1|80|50|50000|0|50|2000|100|50000|10|-50|99|999|9999|-1

  1. Save the file.

  2. Use the SCPOP Utility to convert file back to binary format.

More information

PRT interested process utility configuration.