Description
Check Item Hold Status operates differently depending on the number of destination regions.
If there is only one destination region, Check Item Hold Status eliminates any decisions where the items at the source region specified locations are on Internal or External Hold.
If there are 2+ destination regions, Check Item Hold Status eliminates any decision where the source item is on hold and the destination region is on hold or where the source item is on hold and the destination region is not on hold.
Parameters
This function block has the following parameters:
Parameter |
Description |
|
Always Evaluate |
Hard, Soft or Breakable. This parameter controls what happens when the extension eliminates all available decisions. |
|
|
Hard |
All decisions will remain eliminated. Enter a wait state after the logic script has completed. |
|
Soft |
Roll back any decisions eliminated by this extension. |
|
Breakable |
Roll back any decisions eliminated by this extension that have a danger point value of TRUE (non zero). The routing modules will first use the danger defined for each individual decision; and, if no danger point has been configured for the decision, then the site-wide danger point will be used. If no danger point can be found for a decision, then the decision remains eliminated. |
Item Class |
All items with matching class will be used. |
Check Item Hold Status example. |
|
Check Item Hold Status pseudo code. |
|
Routing function blocks list. |