The following is a sample data_field.idt file:

|-* IDT file generated by IDTPOP utility v1.0

* RECORD: DATA_FIELD DLRP Field Definitions

*

*   0 TABLE_ID          DLRP Table Identifier

*   1 field_id          DLRP Field to be logged

*   2 cimp_type         CIMPLICITY Data Type of Field

*   3 field_len         Size of Field, in cimp_type units

*   4 offset            Offset of field in DLAP buffer

*

ALARM_LOG|alarm_id|12|32|4

ALARM_LOG|alarm_class|12|5|36

ALARM_LOG|resource|3|16|41

ALARM_LOG|logged_by|12|32|57

ALARM_LOG|reference|12|32|89

ALARM_LOG|prev_state|12|1|121

ALARM_LOG|log_action|12|1|122

ALARM_LOG|final_state|12|1|123

ALARM_LOG|alarm_message|12|80|124

ALARM_LOG|timestamp|14|8|208

ALARM_LOG|generation_time|14|8|216

EM_LOG|time|12|22|0

EM_LOG|event_type|12|17|23

EM_LOG|event_source|12|49|41

EM_LOG|action_type|12|17|91

EM_LOG|action_target|12|42|109

EVENT_LOG|alarm_id|12|32|4

EVENT_LOG|alarm_class|12|5|36

EVENT_LOG|resource|3|16|41

EVENT_LOG|logged_by|12|32|57

EVENT_LOG|reference|12|32|89

EVENT_LOG|alarm_message|12|80|124

EVENT_LOG|timestamp|14|8|208

EVENT_LOG|generation_time|14|8|216

PRT_GRP|event_type|12|14|1

PRT_GRP|group_id|12|16|15

PRT_GRP|ext_hold_active|12|1|31

PRT_GRP|ext_hold_reason|12|40|32

PRT_GRP|ext_service_id|12|32|72

PRT_GRP|comment|12|40|104

PRT_GRP|user_id|12|32|144

PRT_ITEM|event_type|12|14|1

PRT_ITEM|entry_time|12|21|15

PRT_ITEM|modify_bitmask|12|4|36

PRT_ITEM|region_1_id|12|16|40

PRT_ITEM|region_1_loc|12|5|56

PRT_ITEM|region_2_id|12|16|61

PRT_ITEM|region_2_loc|12|5|77

PRT_ITEM|tracking_type|12|3|82

PRT_ITEM|item_id|12|20|85

PRT_ITEM|reference_id|12|20|105

PRT_ITEM|item_type_id|12|16|125

PRT_ITEM|assoc_item_id|12|20|141

PRT_ITEM|item_status|12|8|161

PRT_ITEM|int_hold_active|12|1|169

PRT_ITEM|int_hold_reason|12|40|170

PRT_ITEM|ext_hold_active|12|1|210

PRT_ITEM|group_id|12|16|211

PRT_ITEM|num_valid_atts|12|3|227

PRT_ITEM|att_1_name|12|16|230

PRT_ITEM|att_1_value|12|16|246

PRT_ITEM|att_2_name|12|16|262

PRT_ITEM|att_2_value|12|16|278

PRT_ITEM|att_3_name|12|16|294

PRT_ITEM|att_3_value|12|16|310

PRT_ITEM|att_4_name|12|16|326

PRT_ITEM|att_4_value|12|16|342

PRT_ITEM|att_5_name|12|16|358

PRT_ITEM|att_5_value|12|16|374

PRT_ITEM|att_6_name|12|16|390

PRT_ITEM|att_6_value|12|16|406

PRT_ITEM|att_7_name|12|16|422

PRT_ITEM|att_7_value|12|16|438

PRT_ITEM|att_8_name|12|16|454

PRT_ITEM|att_8_value|12|16|470

PRT_ITEM|att_9_name|12|16|486

PRT_ITEM|att_9_value|12|16|502

PRT_ITEM|att_10_name|12|16|518

PRT_ITEM|att_10_value|12|16|534

PRT_ITEM|att_11_name|12|16|550

PRT_ITEM|att_11_value|12|16|566

PRT_ITEM|att_12_name|12|16|582

PRT_ITEM|att_12_value|12|16|598

PRT_ITEM|att_13_name|12|16|614

PRT_ITEM|att_13_value|12|16|630

PRT_ITEM|att_14_name|12|16|646

PRT_ITEM|att_14_value|12|16|662

PRT_ITEM|att_15_name|12|16|678

PRT_ITEM|att_15_value|12|16|694

PRT_ITEM|att_16_name|12|16|710

PRT_ITEM|att_16_value|12|16|726

PRT_ITEM|att_17_name|12|16|742

PRT_ITEM|att_17_value|12|16|758

PRT_ITEM|att_18_name|12|16|774

PRT_ITEM|att_18_value|12|16|790

PRT_ITEM|att_19_name|12|16|806

PRT_ITEM|att_19_value|12|16|822

PRT_ITEM|att_20_name|12|16|838

PRT_ITEM|att_20_value|12|16|854

PRT_ITEM|att_21_name|12|16|870

PRT_ITEM|att_21_value|12|16|886

PRT_ITEM|att_22_name|12|16|902

PRT_ITEM|att_22_value|12|16|918

PRT_ITEM|att_23_name|12|16|934

PRT_ITEM|att_23_value|12|16|950

PRT_ITEM|att_24_name|12|16|966

PRT_ITEM|att_24_value|12|16|982

PRT_ITEM|att_25_name|12|16|998

PRT_ITEM|att_25_value|12|16|1014

PRT_ITEM|att_26_name|12|16|1030

PRT_ITEM|att_26_value|12|16|1046

PRT_ITEM|att_27_name|12|16|1062

PRT_ITEM|att_27_value|12|16|1078

PRT_ITEM|att_28_name|12|16|1094

PRT_ITEM|att_28_value|12|16|1110

PRT_ITEM|att_29_name|12|16|1126

PRT_ITEM|att_29_value|12|16|1142

PRT_ITEM|att_30_name|12|16|1158

PRT_ITEM|att_30_value|12|16|1174

PRT_ITEM|att_31_name|12|16|1190

PRT_ITEM|att_31_value|12|16|1206

PRT_ITEM|att_32_name|12|16|1222

PRT_ITEM|att_32_value|12|16|1238

PRT_ITEM|att_33_name|12|16|1254

PRT_ITEM|att_33_value|12|16|1270

PRT_ITEM|att_34_name|12|16|1286

PRT_ITEM|att_34_value|12|16|1302

PRT_ITEM|att_35_name|12|16|1318

PRT_ITEM|att_35_value|12|16|1334

PRT_ITEM|att_36_name|12|16|1350

PRT_ITEM|att_36_value|12|16|1366

PRT_ITEM|att_37_name|12|16|1382

PRT_ITEM|att_37_value|12|16|1398

PRT_ITEM|att_38_name|12|16|1414

PRT_ITEM|att_38_value|12|16|1430

PRT_ITEM|att_39_name|12|16|1446

PRT_ITEM|att_39_value|12|16|1462

PRT_ITEM|att_40_name|12|16|1478

PRT_ITEM|att_40_value|12|16|1494

PRT_ITEM|comment|12|40|1510

PRT_ITEM|user_id|12|32|1550

PRT_REG|event_type|12|14|1

PRT_REG|region_id|12|16|15

PRT_REG|region_status|12|8|31

PRT_REG|comment|12|40|39

PRT_REG|user_id|12|32|79

SPLIT|operation|12|20|0

SPLIT|data_name|12|55|20

SPLIT|old_value|12|32|75

SPLIT|new_value|12|32|107

SPLIT|comments|12|121|139

SPLIT|n1|7|4|260

SPLIT|n2|7|4|264

PRT_ITEM_ATTR|UUID|12|36|0

PRT_ITEM_ATTR|Attr_Name|12|256|36

PRT_ITEM_ATTR|Attr_Value|12|512|292

RCO_SITE1 |operation|12|20|0

RCO_SITE1|data_name|12|55|20

RCO_SITE1|old_value|12|32|75

RCO_SITE1|new_value|12|32|107

RCO_SITE1|comments|12|121|139

RCO_SITE1|n1|7|4|260

RCO_SITE1|n2|7|4|264

RCO_SITE1|optional|12|80|268

More information

Step 2. Edit the data_field.idt.