One or more log files can be opened in an analysis at the same time.
A pre-filter has to be set to limit the display.
This is possible with five property pages. This filter can be modifies lateron. If the filter is set, only the entries fulfilling these filter criteria are displayed. The entries are listed chronologically.
Another filter possibility is available with the filter columns. Filter criteria can be entered for each column below the column header. The fields support regular expressions, so that also complex filter criteria can be defined.
The list can be sorted ascending or descending by clicking the column headers.
Displayed entries can be saved.
Fields in the log file
IP address/Process ID/Log ID |
These fields identify the clients and allow the allocation of the message. |
Name of log connection |
Shows the connection name. |
Thread ID |
ID of the thread, from which the message was entered. |
Timestamp |
Time of the message in UTC. |
Message Level |
Shows the name of the message level, which entered the message. |
Modules |
Name of the module, which entered the message. |
Optional fields with fix ID.
ID |
Constant |
Description |
---|---|---|
1 |
logid_logname |
Name of the log connection |
2 |
logid_threadname |
Thread name |
3 |
logid_sourcefile |
Source file name |
4 |
logid_sourceline |
Source line |
5 |
logid_assertcond |
Assert condition |
6 |
logid_compname |
Computer name |
7 |
logid_funcname |
Function name |
8 |
logid_prjname |
Project name |
9 |
logid_prjguid |
Project GUID |
A |
logid_prjpath |
Project path |
B |
logid_tx |
Sent data |
C |
logid_rx |
Received data |
D |
logid_serialport |
Number of the serial interface |
E |
logid_baud |
Baudrate |
F |
logid_dtr |
Dtr setting |
10 |
logid_rts |
Rts setting |
11 |
logid_bytesize |
Serial character length |
12 |
logid_parity |
Parity |
13 |
logid_stopbit |
Number of stop bits |
14 |
logid_ctsflow |
CTS |
15 |
logid_dsrflow |
Dsr |
16 |
logid_dsrsens |
Dsr sensitivity |
17 |
logid_port |
Network port number |
18 |
logid_srvname |
Server name |
19 |
logid_sbname |
Standby name |
1A |
logid_cliname |
Client name |
1B |
logid_srvIP |
Server IP address |
1C |
logid_sbIP |
Standby IP address |
1D |
logid_cliIP |
Client IP address |
1E |
logid_bindump |
Binary buffer |
1F |
logid_ptr |
Pointer |
20 |
logid_classname |
Class name |
21 |
logid_errcode |
Error code |
22 |
logid_dllinstance |
DLL instance handle |
23 |
logid_dllname |
DLL name |
24 |
logid_errpar1 |
Driver error parameter 1 |
25 |
logid_errpar2 |
Driver error parameter 2 |
26 |
logid_trace |
Trace message |
27 |
logid_errortxt |
Error text |
28 |
logid_errorfile |
Error file name |
29 |
logid_succeedcond |
Condition for success |
2A |
logid_succeedvalue |
Value when successful |
2B |
logid_net |
Net address |
2C |
logid_db |
Data block |
2D |
logid_ofs |
Offset |
2E |
logid_bit |
Bit number |
2F |
logid_area |
Area in PLC |
30 |
logid_dir |
Shows the direction of the communication in a string. |
31 |
logid_txt |
General text |
32 |
logid_mainvers |
Main version number |
33 |
logid_minorvers |
Minor version number |
34 |
logid_buildvers |
Build number |
35 |
logid_sp |
Service pack |
36 |
logid_hotfix |
Hotfix number |
37 |
logid_clisrc |
Client, which sent the command |
38 |
logid_clidst |
Client, which is the target for the command |
39 |
logid_pvid |
Datapoint number (channel number) |
3A |
logid_pvname |
Datapoint name |
3B |
logid_pvvalue |
Value of datapoint |
3C |
logid_pvstatus |
Status of datapoint |
3D |
logid_pvtime |
Time stamp of datapoint in sec |
3E |
logid_duration |
Time duration in ms |
3F |
logid_cnt |
Number, counter |