Recipe single with onlinedialog

Previous chapterNext chapter Show allShow all    Hide allHide all

This function is used to select and change a recipe before it is issued during online operation (change of set value).

Give the recipe as the transfer parameter. This function is configured via a dialog mask.

In the Runtime the recipe selection is opened.

Configurable entries are


create a new recipe


copy selected recipe and save it under a new name


Change the name of the selected recipe


delete selected recipe

The new recipe is available in the recipe list.

Configurable options are:

Add variable

add a new variable to the recipe

Release variable

remove a variable from the recipe

Edit set value

change the values of the recipe

In order to prevent changes to the recipe entries and at the same time permit selection of the individual recipes during online operation, make an entry in the ZENON6.INI file.




0 - change not permitted

1 - change permitted (default)