Property |
Description |
Values |
Columns list |
Specifies the data sources configured in the grid. The item Default Column Settings lets you configure the format, thresholds, and general properties of all columns. To change settings for a specific column, ensure that column is selected. NOTE: To change the name of a column, double-click the column name and enter the new name. |
Arrow buttons – allow you to change the order of the columns. Row Header check box – when selected, indicates that the column is used as a row header. Visible check box – when selected, indicates that the column is visible. The column is hidden if the check box is cleared. Editable check box – when selected, indicates that values in the column can be changed. Auto Fill Data check box – when selected, indicates that the data in the selected column will be repeated on each row. This check box is used only for those columns with data that will be the same for every row. |
Apply |
Indicates whether you want to apply the first data source's configuration options to all other data sources. For example, both simulation1 and simulation2 have value, timestamp, and quality columns. All of simulation1's three column configurations will apply to simulation3's columns. |
Selected – the configuration options of the first column apply to all other columns. Cleared – the configuration options of the first column do not apply to all other columns. |
Group Columns |
Indicates whether all displayed columns will be grouped by their source during run-time. This check box is available only for real time data sources. |
Selected – the columns are grouped by data source. Cleared – the columns are not grouped by data source. |
General tab |
Specifies the properties for each data source. If you select a specific column, you can override these defaults. |
Refer to General Tab (Grid Columns Tab) for specific information on these fields. |
Threshold tab |
Specifies the thresholds for each data source. If you select a specific column, you can override the default threshold values. |
Refer to Threshold Tab (Grid Columns Tab) for specific information on these fields. |
Format tab |
Specifies how to format data for each data source. If you select a specific column, you can override the default format settings. |
Refer to Format Tab (Grid Columns Tab) for specific information on these fields. |
Enumeration |
Specifies a list of values that a user can choose from to update a column during run-time or insert. |
Refer to Enumeration Tab (Grid Columns Tab) for specific information on these fields. |
Property |
Description |
Values |
Use Default |
Indicates whether the grid uses the default enumeration settings. |
Selected – the grid uses the default settings. Cleared – the grid uses configured settings. |
Enable |
Indicates whether the selected column uses the enumeration settings specified. |
Selected – the column uses the enumeration settings as specified. Cleared – the column does not use enumeration settings. |
Data Bound |
Indicates that the enumeration values are retrieved from a data source. |
N/A |
Data Source |
Specifies the data source that the enumeration values are retrieved from. |
Configure Data Source button – displays the Data Source Browser. See Data Source Browser Properties. Configure Expression button – displays the Expression Builder. See Expression Builder Properties. |
Manually |
Indicates that the enumeration values are manually set (i.e. they are not retrieved from a data source). |
N/A |
String list |
Specifies the list of enumeration values. |
Add Strings button – displays the Add Strings dialog. Enter each value in this dialog. Press Enter on your keyboard to separate values. Delete Selected Item button – removes the selected item from the enumeration list. |