Properties on the Legends Tab (Style Options
Tab)
Property
|
Description
|
Values
|
Foreground
Color button
|
The color of the text in the legend.
This button is available when the Use Pen
Line Color check box is cleared.
|
Select a color from the color palette.
|
Use Pen
Color
|
Specifies whether the color of the legend's
text will match the chart's pen color.
|
Selected – legend matches pen color.
Cleared – legend uses a different color.
Foreground Color button is enabled.
|
Background
Color button
|
The background color of the each cell in the
legend.
This button is available when the Use Plot
Background Color check box is cleared.
|
Select a color from the color palette.
|
Use Plot
Background Color
|
Specifies whether the legend's background
color will match the color of the chart's plotting area. This check
box is available only if the Transparent check box is cleared.
|
Selected – background color matches.
Cleared – background uses a different color.
Background Color button is enabled.
|
Foreground
Highlight Color
button
|
The color used to indicate that a data
source is selected in the legend.
This button is available when the Use Pen
Line Color check box is cleared.
|
Select a color from the color palette.
|
Use Pen
Color
|
Specifies whether the text color of the data
source selected from the legend will match the chart's pen
color.
|
Selected – highlight color matches pen.
Cleared – highlight color uses a different
color. Foreground Highlight Color button is enabled.
|
Background
Highlight Color
button
|
The cell color of the selected row in the
legend.
This button is available when the Use Plot
Background Color check box is cleared.
|
Select a color from the color palette.
|
Use Plot
Background Color
|
Specifies whether the background cell color
of the selected row in the legend will match the color of the
chart's plotting area. This check box is available only if the
Transparent check box is cleared.
|
Selected – background highlight color
matches plot background.
Cleared – background highlight color uses a
different cell color for the selected row. Background Highlight
Color button is enabled.
|
Header
Foreground
Color button
|
The color of the column header text in the
legend.
This button is available when the Use Title
Foreground Color check box is cleared.
|
Select a color from the color palette.
|
Use Title
Foreground Color
|
Specifies whether the color of the column
header text will match the color of the chart's title text.
|
Selected – column header color matches title
text.
Cleared – column header uses a different
color. Header Foreground button is enabled.
|
Header
Background
Color button
|
The background color of each header cell in
the legend.
This button is available when the Use Chart
Background Color check box is cleared.
|
Select a color from the color palette.
|
Use Chart
Background Color
|
Specifies whether the background color of
each legend header cell will match the chart background color.
|
Selected – header background color matches
chart background.
Cleared – header background color uses a
different color. Header Background button is
enabled.
|
Maximum Rows Displayed
|
The maximum number of pens to display when
legend scrolling is enabled.
|
1 to 30 pens.
When Enable Row Scrolling check box is
cleared, the legend shows all pens in the chart.
|
Enable Row
Scrolling
|
Specifies whether scrolling for the chart's
legend is enabled.
Use this feature to save space in the chart
by minimizing the size of the legend.
|
Selected – legend shows the number of pens
defined by the Maximum Row Displayed field and adds a scroll bar so
that you can scroll through the pens in the chart.
Cleared – legend scrolling is disabled.
|
Hide Legend
Header
|
Specifies whether the legend header is
shown.
|
Selected – hides the header.
Cleared – shows the header.
|
Display Selected
Row Bold
|
Specifies whether to display the text of the
selected data source in boldface.
|
Selected – selected data source is bold.
Cleared – selected data source is in plain
text.
|
Show Icons
|
Specifies whether to display a small image
of each pen in the chart.
|
Selected – icons are visible.
Cleared – icons are hidden.
|