Properties in the Edit Tree Configuration Dialog Box:
Threshold Tab
Property
|
Description
|
Values
|
Enable Threshold
|
Indicates whether the tree uses the
threshold settings configured.
|
Selected – the data in the tree is formatted
according to the threshold properties.
Cleared – the threshold settings are not
used.
|
Apply to
Foreground/
Color
|
Indicates that the threshold colors are
applied to the foreground (text) in the tree.
|
If not selected, the threshold colors are
applied to the tree background color.
|
Apply to
Background
Color
|
Indicates that the threshold colors are
applied to the background color of the tree.
|
If not selected, the set colors are applied
to the tree foreground color.
|
Range
|
Specifies a threshold range. Column values
that fall within a specific range appear with the color associated
with that threshold range.
|
N/A
|
Exact Match
|
Specifies an exact threshold value. Column
values must equal the specified threshold to pick up the associated
threshold color.
|
N/A
|
Tolerance field
|
Specifies the maximum amount of allowable
deviation from the thresholds defined. For example, if you set the
tolerance to 0.1 and the threshold is 20, then values from 20.00
and 20.09 are treated as 20.
|
Any numeric value.
|
Edit out of
Range button
|
Allows you to set options for the appearance
of values that fall outside of the threshold values/ranges you have
set.
|
Opens the Edit Out of Range dialog box.
Options are:
Out of Range – indicates whether to mark out
of range values (selected indicates they will be marked).
Color – indicates the color that out of
range values will be displayed in. Select a color from the
palette.
|
Minimum
Column
|
Specifies the minimum threshold value for
the range you want to define.
|
Any numeric value.
|
Maximum
Column
|
Specifies the maximum threshold value for
the range you want to define.
|
Any numeric value.
|
Color By
column
|
Specifies the threshold color.
|
Select a color from the color palette.
|
Add button
|
Adds a row to the end of the threshold
table.
|
N/A
|
Insert button
|
Inserts a row above the selected row in the
threshold table.
|
N/A
|
Delete button
|
Removes the selected row from the threshold
table.
|
N/A
|
Delete all rows
button
|
Clears the entire threshold table.
|
N/A
|
Move Row(s)
Up/Move Row(s)
Down buttons
|
Changes the order of the selected
row(s).
|
N/A
|
Load button
|
Loads a threshold file.
|
Select a table from the Load Threshold Table
dialog box.
|
Save button
|
Saves a set of thresholds to a file.
|
N/A
|
Save As
button
|
Saves a set of thresholds to a file with a
new name.
|
Specify a the table name in the Save
Threshold Table dialog box.
|
Reset button
|
Restores the thresholds to their default
values.
|
N/A
|