Properties on the Chart Tab (Variable Charts
only)
Property
|
Description
|
Values
|
Subgroup Size
|
Indicates whether to display the subgroup
size in Tool Tips.
|
Selected –
subgroup size is shown in Tool Tips
Cleared –
sample size is not shown in Tool Tips.
|
Value
|
Indicates whether to display the value or
the plotted data point in Tool Tips.
|
Selected – the
value is shown in Tool Tips.
Cleared – the
value is not shown in Tool Tips.
|
Subgroup ID
|
Indicates whether to display the subgroup ID
in Tool Tips.
|
Selected – the
subgroup ID is shown in Tool Tips.
Cleared – the
subgroup ID is not shown in Tool Tips.
|
Enable
|
Indicates whether to display Tool Tips when
the cursor moves over data points on the chart.
|
Selected – Tool
Tips are shown when the cursor moves over data points.
Cleared – Tool
Tips are not shown when the cursor moves over data points.
|
Use Series
Color
|
Indicates whether to use the color that is
set for the series (data column) as the color for the associated
Tool Tip. The series color is set on the Data tab.
|
Selected – the
background color of Tool Tips matches the color of the associated
series (data column).
Cleared – the
background color of all Tool Tips is the default color.
|
Decimal
Places
|
Specifies the number of decimal places to
display on the Tool Tips for sample size and P value.
|
Values 0 - 7
|
Control Limits:
Calculated From
Data
|
Indicates that the control limits will be
calculated from the sample data.
|
Sigma Limit – a
value (1.0 to 5.0) that indicates the number of equal parts (one
standard deviation each) that can appear from the center line
before the system is considered unstable. For example, if the sigma
limit is 3, then a point on the chart must be more than 3 standard
deviations from the average (center line) to be considered out of
control.
|
Control Limits:
Specified
|
Indicates that control limits are derived
from data sources or are set as specific values for upper control
limit (UCL), center line (CL), and lower control limit (LCL).
|
Constant –
allows you to specify values for UCL, CL, and LCL.
Data Source –
values for UCL, CL, and LCL are specified from a data source.
NOTE: For the XBar-R chart, specify
limits for both XBar and Range controls. For the XBar-S chart,
specify limits for both XBar and Sigma controls.
|
Control Limits:
Based on Mean
& Sigma
NOTE: For Range,
Sigma, and Moving Range charts this option button is labeled `Based
on Sigma' and the mean is not included.
|
Indicates that mean and standard deviation
values are derived from data sources or are set as specific
values.
|
Constant –
allows you to specify values for mean and standard deviation.
Data Source –
values for mean and standard deviation are specified from a data
source.
Sigma Limit –
see Control Limits: Calculated From Data (above) for a definition
of sigma limit.
|
Control Limits: From VisualSPC Connector
|
Indicates that the control limits are
derived from the VisualSPC connector.
|
If the data source is from a VisualSPC
connector, this option is the default.
|